{"product_id":"yokogawa-f3da04-6r-stardom-4-channel-analog-output-module","title":"YOKOGAWA F3DA04-6R STARDOM 4-Channel Analog Output Module","description":"\u003ch2\u003eYOKOGAWA F3DA04-6R STARDOM Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for stable and accurate analog output signals in STARDOM network environments, the \u003cstrong\u003eYOKOGAWA F3DA04-6R\u003c\/strong\u003e (\u003cstrong\u003eF3DA04\u003c\/strong\u003e Analog Output Module) provides direct physical\/electrical execution. This hardware component functions as a 4-channel controller link executing digital-to-analog data conversion to drive external field actuators. The module translates digital register commands into precise electrical control loops, maintaining physical process automation control variables across distributed control networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eF3DA04-6R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg (2.00 lbs shipping weight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e13.0 x 13.0 x 3.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC external supply nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e4 analog output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Types\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC, 1-5 V DC (supports -10 to +10 VDC, 0-20 mA matrices)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12-bit D\/A conversion (up to 16-bit high-res ADC sampling paths)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Resistance\u003c\/td\u003e\n\u003ctd\u003e250 ohm (current limits), 2 kohm or higher (voltage limits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Rating\u003c\/td\u003e\n\u003ctd\u003eChannel-to-system isolation, 1500 VAC withstand voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e10 ms or less (sampling up to 50 us\/point paths)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination Matrix\u003c\/td\u003e\n\u003ctd\u003eFront-facing integrated connector pins\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e5 to 95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; DCS Module Attributes\u003c\/h3\u003e\n\u003cp\u003eThe module architecture deploys a dedicated 4-20 mA HART loop protocol interface to regulate continuous electronic loop transmitters. The integrated galvanic barrier enforces high-efficiency channel-to-system isolation rated at 1500 VAC, which blocks hazardous voltage spikes and isolates ground loops across adjacent output lines. This isolation scheme prevents external electromagnetic currents from disrupting the conversion resolution of the digital-to-analog converter chips. The system automatically balances reference signals against localized terminal variations, ensuring consistent current driving performance without dropping loop stability during high-load operations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the module react if the load impedance falls below the technical limits?\u003c\/p\u003e\n\u003cp\u003eA: Dropping load resistance below 250 ohm on current loops or 2 kohm on voltage loops causes thermal overload in the output driving circuit, which triggers internal diagnostic flags and disrupts loop accuracy.\u003c\/p\u003e\n\u003cp\u003eQ: Is this module hot-swappable while the main STARDOM base unit is actively powered?\u003c\/p\u003e\n\u003cp\u003eA: No, interrupting backplane current distribution without performing a systematic software shutdown induces transient voltage changes that risk corrupting system data or damaging internal microcomponents.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Insertion Alignment:\u003c\/strong\u003e Align the rear interface connector with the backplane rail slot perfectly before pushing the card into the rack frame to avoid bending the physical pin matrix.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Shield Routing:\u003c\/strong\u003e Encapsulate all 4-20 mA current loops in twisted pair shielded cables, landing the outer metallic braid at the central cabinet grounding bar to suppress noise induction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInductive Load Protection:\u003c\/strong\u003e Install external surge suppression diodes or varistors directly across any connected inductive actuator coils to block reverse voltage counter-EMF spikes from entering the terminal paths.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Space Separation:\u003c\/strong\u003e Maintain a standard minimum physical distance of 150 mm between these low-voltage analog output wires and any industrial AC motor grids to guarantee channel-to-channel signal integrity.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43681297793114,"sku":"F3DA04-6R","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/617..jpg?v=1784526909","url":"https:\/\/www.spareoil.com\/products\/yokogawa-f3da04-6r-stardom-4-channel-analog-output-module","provider":"SpareOil Automation","version":"1.0","type":"link"}