{"product_id":"yokogawa-f3wd32-3f-fa-m3-transistor-digital-i-o-module","title":"Yokogawa F3WD32-3F FA-M3 Transistor Digital I\/O Module","description":"\u003ch2\u003eYokogawa F3WD32-3F Digital I\/O Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa F3WD32-3F\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eF3WD32-3F\u003c\/strong\u003e Digital I\/O Module, operates as a dedicated hardware component for 32-point discrete input and transistor output signal processing within FA-M3 Value II PLC platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eF3WD32-3F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.11 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e30 mm (W) x 100 mm (H) x 110 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e100 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Points\u003c\/td\u003e\n\u003ctd\u003e16 points (24 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Points\u003c\/td\u003e\n\u003ctd\u003e16 points (transistor sink type, 24 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e20.4 to 26.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e4.1 mA per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e0.1 A per point (0.4 A per common line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time (Input)\u003c\/td\u003e\n\u003ctd\u003eON \u0026lt;= 2 ms \/ OFF \u0026lt;= 3.5 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time (Output)\u003c\/td\u003e\n\u003ctd\u003eON\/OFF \u0026lt;= 1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003ePhotocoupler isolation, 1500 VAC for 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Connector\u003c\/td\u003e\n\u003ctd\u003e40-pin shared connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e20 to 90% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail via FA-M3 base unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation \u0026amp; Signal Integrity\u003c\/h3\u003e\n\u003cp\u003eThe Yokogawa F3WD32-3F incorporates high-speed photocoupler circuitry to isolate external field signals from internal FA-M3 backplane logic. This design maintains an electrical isolation threshold of 1500 VAC for 1 minute between field terminals and module CPU connections, suppressing industrial electrical noise and common-mode surge propagation. Furthermore, the 16 transistor sink outputs switch 24 VDC loads with sub-millisecond switching latencies (\u0026lt;= 1 ms), while configurable digital input filtering filters contact bounce across the 16 input channels.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 40-pin shared connector split input and output channels into separate terminal blocks?\u003c\/p\u003e\n\u003cp\u003eA: Both the 16 digital inputs and 16 transistor outputs terminate on the single 40-pin connector header, requiring external branch cables or breakout terminal units to route field signals cleanly.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle inductive switching spikes on the 16 transistor outputs?\u003c\/p\u003e\n\u003cp\u003eA: Internal solid-state output circuitry handles switching loads up to 0.1 A per channel, but inductive field loads such as solenoids or relay coils require external suppression diodes wired across the load to absorb back-EMF voltage transients.\u003c\/p\u003e\n\u003cp\u003eQ: Can input response times be configured to filter noisy contact chatter?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the input circuit response time defaults to fast switching (\u0026lt;= 2 ms ON \/ \u0026lt;= 3.5 ms OFF) but allows internal software-configured delays up to 18.5 ms for debounce filtering on slow field contacts.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eField engineers must execute standard installation protocols when integrating the F3WD32-3F module into an FA-M3 rack:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eDe-energize the base unit power supply prior to sliding the module into its rack slot and tightening the retaining screws.\u003c\/li\u003e\n\u003cli\u003eWire external surge suppression diodes directly across all inductive DC loads to protect the transistor sink output stages from voltage inductive spikes.\u003c\/li\u003e\n\u003cli\u003eKeep field I\/O wiring running through the 40-pin cable assembly physically separate from high-voltage AC lines and variable frequency drive motor leads.\u003c\/li\u003e\n\u003cli\u003eAlign the 40-pin terminal connector straight before pressing it fully onto the module header, confirming that side locking mechanisms latch firmly.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43901437476954,"sku":"F3WD32-3F","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/63_c5593f4d-67bb-48e1-9fb4-dcb53f7179cb.jpg?v=1787620159","url":"https:\/\/www.spareoil.com\/products\/yokogawa-f3wd32-3f-fa-m3-transistor-digital-i-o-module","provider":"SpareOil Automation","version":"1.0","type":"link"}