{"product_id":"yokogawa-f3wd64-3f-f3wd64-fa-m3-digital-i-o-module","title":"Yokogawa F3WD64-3F F3WD64 FA-M3 Digital I\/O Module","description":"\u003ch2\u003eYokogawa F3WD64-3F FA-M3 Digital I\/O Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-density discrete signal interface processing in FA-M3 PLC racks, the \u003cstrong\u003eYokogawa F3WD64-3F\u003c\/strong\u003e (\u003cstrong\u003eF3WD64\u003c\/strong\u003e Digital I\/O Module) provides direct physical\/electrical execution. The module integrates 32 24 VDC input channels alongside 32 transistor-source output channels to execute fast-cycle logic execution across two 40-pin front connectors.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe base ordering code defines the output stage architecture and channel density:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eF3WD64\u003c\/strong\u003e: Base model designation for 64-point high-density digital I\/O hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-3F\u003c\/strong\u003e: Transistor-source output configuration variant featuring 32 inputs and 32 outputs with internal protection circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eF3WD64-3F \/ F3WD64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e120 g (0.26 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e100 mm x 28 mm x 90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e170 mA at 5 VDC (backplane), 55 mA at 24 VDC (external supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channel Count\u003c\/td\u003e\n\u003ctd\u003e32 points (24 VDC, 4.1 mA per channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channel Count\u003c\/td\u003e\n\u003ctd\u003e32 transistor-source points (24 VDC, 0.1 A per channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Isolation\u003c\/td\u003e\n\u003ctd\u003ePhotocoupler isolation, 1500 VAC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003eDual 40-pin connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eOptical isolation channels utilize photocoupler barriers to isolate field-side 24 VDC wiring from the main 5 VDC logic backplane bus. Photocoupler isolation blocks ground loops and prevents voltage spikes generated by field actuators from entering internal controller logic circuits. Built-in active clamping, short-circuit protection, and thermal shutdown circuits safeguard transistor-source outputs against field overload conditions, preserving system stability near heavy analog instrumentation loops.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the maximum output current rating per common group on the F3WD64-3F?\u003c\/p\u003e\n\u003cp\u003eA: Each transistor-source output channel supports up to 0.1 A, with a maximum current limit of 0.4 A allowed per 8-point common group.\u003c\/p\u003e\n\u003cp\u003eQ: Which input sampling filter settings are configurable on the module?\u003c\/p\u003e\n\u003cp\u003eA: The input response filter can be configured for delay settings of 0 us, 62.5 us, 250 us, or 1 ms to eliminate field contact bounce.\u003c\/p\u003e\n\u003cp\u003eQ: Can the 40-pin field wiring connectors be removed without shutting down system logic?\u003c\/p\u003e\n\u003cp\u003eA: Yes, field wiring connectors can be detached, provided external 24 VDC field load power is disconnected prior to removal to prevent inductive arcing.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the module firmly into its slot on the FA-M3 base unit, securing the top retention screw to establish solid backplane contact. Route incoming 24 VDC input lines and output load cables through shielded multi-conductor cables attached to the dual 40-pin connectors. Ensure cable shield braids ground directly to the cabinet enclosure bar using low-impedance grounding clamps. Separate 24 VDC field power lines from high-voltage AC motor wiring to minimize capacitive noise coupling.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43882770104410,"sku":"F3WD64-3F","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/872..jpg?v=1787292435","url":"https:\/\/www.spareoil.com\/products\/yokogawa-f3wd64-3f-f3wd64-fa-m3-digital-i-o-module","provider":"SpareOil Automation","version":"1.0","type":"link"}