{"product_id":"yokogawa-f3xd16-3f-fa-m3-series-digital-input-module","title":"YOKOGAWA F3XD16-3F FA-M3 Series Digital Input Module","description":"\u003ch2\u003eYOKOGAWA F3XD16-3F Digital Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for discrete signal acquisition in FA-M3 PLC platforms, the \u003cstrong\u003eYOKOGAWA F3XD16-3F\u003c\/strong\u003e (\u003cstrong\u003eF3XD16-3F\u003c\/strong\u003e Digital Input Module) provides direct physical\/electrical execution of 16-channel 24 V DC signal monitoring.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eF3XD16\u003c\/strong\u003e: Base model identifier for 16-point digital input functionality.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-3F\u003c\/strong\u003e: Version suffix indicating specific hardware revision, terminal configuration, and backplane bus compatibility standards for the FA-M3 series.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eF3XD16-3F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.16 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e120 × 90 × 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 V DC, 65 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 (Sink\/Source)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e4.1 mA \/ point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e5, 15, 25, or 40 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePLC Control \u0026amp; Deterministic Network Attributes\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eF3XD16-3F\u003c\/strong\u003e utilizes high-speed photocoupler isolation to interface between field-level 24 V DC signals and the FA-M3 backplane logic. The module supports deterministic network timing, with configurable input filtering (5 ms to 40 ms) to suppress contact bounce and electromagnetic transients on field lines. To ensure firmware flash compatibility and synchronization with the CPU module, the device implements backplane bus communication velocity management. The module's I\/O density scaling allows it to operate efficiently within high-density control racks while maintaining the necessary optical barrier to prevent fault propagation from the field wiring to the controller logic.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does this module support both sinking and sourcing input configurations?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the F3XD16-3F is designed for dual sink\/source compatibility, allowing the user to configure the common potential based on the field sensor switching requirements.\u003c\/p\u003e\n\u003cp\u003eQ: Can the input response time be adjusted during runtime?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the input response time is software-configurable per input point, allowing users to tune signal filtering based on the specific mechanical or electrical noise profile of the attached device.\u003c\/p\u003e\n\u003cp\u003eQ: Is this module hot-swappable?\u003c\/p\u003e\n\u003cp\u003eA: No. Power to the FA-M3 base unit must be removed prior to the insertion or extraction of the F3XD16-3F to prevent potential damage to the module's backplane connector pins.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: Secure the module onto the FA-M3 base unit rack. Verify that the unit is firmly locked in place to maintain the ground contact required for electromagnetic immunity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring\u003c\/strong\u003e: Connect field devices to the 18-point M3.5 terminal block. Use shielded twisted-pair cabling for long runs to mitigate inductive coupling from high-voltage AC lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding\u003c\/strong\u003e: Ensure that the PLC chassis ground is connected to a low-impedance earth point. Keep the input circuit return path as short as possible to minimize potential differences.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation\u003c\/strong\u003e: Maintain a minimum clearance of 100 mm between signal wiring and high-current power cables to preserve the effectiveness of the module's internal optical isolation barriers.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43648923205722,"sku":"F3XD16-3F","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/180_6ce13368-70ea-4781-830b-c9a4e4f1e16c.jpg?v=1783905652","url":"https:\/\/www.spareoil.com\/products\/yokogawa-f3xd16-3f-fa-m3-series-digital-input-module","provider":"SpareOil Automation","version":"1.0","type":"link"}