{"product_id":"yokogawa-ks1-10b-centum-vp-ks1-signal-cable-assembly","title":"Yokogawa KS1-10B CENTUM VP KS1 Signal Cable Assembly","description":"\u003ch2\u003eYokogawa KS1-10*B KS1 Signal Cable\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-integrity signal transmission in CENTUM VP and CS3000 Field I\/O systems, the \u003cstrong\u003eYokogawa KS1-10*B\u003c\/strong\u003e (\u003cstrong\u003eKS1-10*B\u003c\/strong\u003e Signal Cable) provides direct physical\/electrical execution. This system cable assembly interconnects ESB bus adapters, node units, and I\/O modules across Yokogawa DCS installations without signal degradation. The assembly establishes a robust 40-pin to 40-pin link, delivering factory-terminated wiring that resists environmental stress and severe electromagnetic interference in continuous industrial processes.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCode \/ Suffix Segment\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eConfiguration Detail\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eFunctional Specification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Model: KS1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSignal Cable Assembly\u003c\/td\u003e\n\u003ctd\u003e40-pin to 40-pin system interface cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLength Suffix: -10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 m Cable Length\u003c\/td\u003e\n\u003ctd\u003eFixed factory pre-assembled length of 10 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e*\u003ci\u003eStyle Code: B\u003c\/i\u003e\n\u003c\/td\u003e\n\u003ctd\u003eStyle B Design\u003c\/td\u003e\n\u003ctd\u003eRevision B construction and connector strain-relief variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKS1-10*B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 m (Cable Length)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePassive component (3 A current capacity per path)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40-pin to 40-pin factory-terminated plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCharacteristic Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShielding Style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndustrial EMI\/RFI shielded twisted pair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10% to 95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYokogawa CENTUM VP, CS3000, and ESB bus frame units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, UL industrial cabling standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe Yokogawa KS1-10*B cable maintains maximum field signal fidelity by utilizing high-density shielded twisted pairs designed to suppress cross-channel noise and common-mode voltage spikes. In dense process control architectures, low-level analog signals (such as 4-20 mA HART loops) and discrete I\/O vectors transit through the 40-pin boundary simultaneously. The cable insulation dielectric and optimized characteristic impedance (75 Ohm) prevent cross-talk between adjacent pins, ensuring that automated field device calibrations, digital HART multi-drop data overlays, and critical process measurement loops pass through the DCS backplane interfaces without signal distortion or attenuation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What physical precautions are required when routing the 40-pin connectors through tight cabinet paths?\u003c\/p\u003e\n\u003cp\u003eA: Engineers must maintain the factory-molded strain relief area during installation. Do not bend the cable within 100 mm of the 40-pin plug housing, as dynamic tension distorts internal pin alignment and compromises EMI shielding continuity.\u003c\/p\u003e\n\u003cp\u003eQ: Can the KS1-10*B cable be field-cut or field-spliced if the 10 m length is too long?\u003c\/p\u003e\n\u003cp\u003eA: No, field cutting or splicing is strictly prohibited. The cable features factory-terminated 40-pin connectors with precise impedance matching (75 Ohm) and continuous internal shield drain networks; cutting breaks the factory-sealed EMI shielding and invalidates CE\/UL compliance.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eWhen installing the Yokogawa KS1-10*B cable assembly, field engineers must strictly follow industrial wiring protocols to prevent communication errors and mechanical failure:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eTurn off power to the destination DCS I\/O rack or node unit before mating or un-mating the 40-pin connectors to prevent accidental short circuits across adjacent pin headers.\u003c\/li\u003e\n\u003cli\u003eRoute the 10 m cable through dedicated, grounded metallic wireways or cable trays, keeping a minimum distance of 300 mm from high-voltage AC power lines and variable frequency drive (VFD) output leads.\u003c\/li\u003e\n\u003cli\u003eVerify that the 40-pin connector faces match the keying slots on the Yokogawa module header, then push the plug firmly into place until the locking latches snap completely over the connector housing.\u003c\/li\u003e\n\u003cli\u003eSecure the cable drain wire to the local cabinet earth ground bus bar using a low-impedance grounding strap to ensure effective EMI\/RFI dissipation.\u003c\/li\u003e\n\u003cli\u003eAvoid pulling the cable around sharp metal corners or exceeding the minimum static bend radius of 120 mm during tray deployment.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43855756886106,"sku":"KS1-10*B","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/427_a3550a8a-9cf3-475f-b757-80b2a4fb3d54.jpg?v=1786932993","url":"https:\/\/www.spareoil.com\/products\/yokogawa-ks1-10b-centum-vp-ks1-signal-cable-assembly","provider":"SpareOil Automation","version":"1.0","type":"link"}