{"product_id":"yokogawa-sbd4d-06-centum-vp-terminal-board-for-digital","title":"Yokogawa SBD4D-06 Centum VP Terminal Board for Digital","description":"\u003ch2\u003eYokogawa SBD4D-06 Field I\/O Terminal Board\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa SBD4D-06\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eSBD4D-06\u003c\/strong\u003e Terminal Board for Digital, operates as a dedicated hardware component for field wiring termination and digital output signal distribution within Yokogawa Centum VP Field I\/O (FIO) platforms. Configured for single or dual-redundant configurations, the unit bridges 16-channel digital output modules such as the SDV144 and SDV541 to field-side solenoids, actuators, and indicators.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Details\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSBD4D\u003c\/td\u003e\n\u003ctd\u003eBase Model Code\u003c\/td\u003e\n\u003ctd\u003eTerminal Board for Digital I\/O Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-0\u003c\/td\u003e\n\u003ctd\u003eSuffix Code 1\u003c\/td\u003e\n\u003ctd\u003eAlways 0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003eSuffix Code 2\u003c\/td\u003e\n\u003ctd\u003eWith ISA Standard G3 conformal coating, no explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSBD4D-06\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e130 x 107.5 x 32.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e0.6 A at 24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Capacity\u003c\/td\u003e\n\u003ctd\u003e16 channels x 1 (supports up to 64 channels in module family)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eSingle and Dual-redundant execution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN-rail mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Protection\u003c\/td\u003e\n\u003ctd\u003eISA Standard G3 harsh atmosphere conformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Current\u003c\/td\u003e\n\u003ctd\u003e0.5 A per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e1500 VAC channel-to-system bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Switching Response\u003c\/td\u003e\n\u003ctd\u003eLess than or equal to 1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e10 to 90% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Loop Integration Features\u003c\/h3\u003e\n\u003cp\u003eDesigned specifically for Yokogawa DCS process environments, this terminal assembly delivers channel-to-system galvanic isolation rated for 1500 VAC, preventing ground loops and transient spikes from entering the control backplane. The ISA Standard G3 conformal coating protects physical conductor paths against corrosive atmospheres present in demanding chemical processes. In dual-redundant wiring layouts, the board maintains seamless switching behavior, ensuring signal continuity across 24 VDC current loops during redundant module failovers.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the SBD4D-06 terminal board support direct hot-swapping of connected FIO digital modules?\u003c\/p\u003e\n\u003cp\u003eA: Yes, host FIO digital modules connected via the terminal board interface can be removed and replaced under power without interrupting field power lines or disturbing adjacent wiring paths.\u003c\/p\u003e\n\u003cp\u003eQ: What environmental protection rating does suffix code \"-06\" provide?\u003c\/p\u003e\n\u003cp\u003eA: The \"-06\" suffix indicates that the PCB assembly includes ISA Standard G3 conformal coating for exposure to airborne corrosive contaminants, configured without intrinsic safety explosion protection.\u003c\/p\u003e\n\u003cp\u003eQ: How is the physical grounding managed across the terminal board?\u003c\/p\u003e\n\u003cp\u003eA: Channel logic isolation is maintained up to 1500 VAC relative to the system bus. Field cable shields terminate at designated ground bus bars to prevent noise coupling into the FIO interface.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the SBD4D-06 securely onto a standard DIN-rail within the field termination cabinet, verifying that spring locks snap firmly into place. Connect field cables to the designated screw terminals, ensuring wires are stripped correctly without exposed conductors. Route all field 24 VDC signal lines separately from AC power lines within cabinet wireways to avoid inductive noise coupling. When wiring for dual-redundant module configurations, verify that both interconnecting system cables are fully locked into their respective module connectors before energizing the system.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43831972528218,"sku":"SBD4D-06","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/11_d7dc6c1e-376d-4530-b1bf-400ff81679dc.jpg?v=1786502846","url":"https:\/\/www.spareoil.com\/products\/yokogawa-sbd4d-06-centum-vp-terminal-board-for-digital","provider":"SpareOil Automation","version":"1.0","type":"link"}