{"product_id":"yokogawa-ssc60d-f2541-prosafe-rs-sil3-duplexed-safety-control-unit","title":"Yokogawa SSC60D-F2541 ProSafe-RS SIL3 Duplexed Safety Control Unit","description":"\u003ch2\u003eYokogawa SSC60D-F2541 Safety Control Unit\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa SSC60D-F2541\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eSSC60D\u003c\/strong\u003e Duplexed Safety Control Unit, operates as a dedicated hardware component for SIL3-certified safety logic execution within ProSafe-RS Safety Instrumented Systems. Configured with dual-redundant CPU architecture and dual Vnet\/IP communication interfaces, the unit executes deterministic 100 ms safety cycles and fail-safe diagnostic routines inside Safety Control Stations (SCS). Dual ESB bus integration maintains continuous data processing to bring processes to a defined safe state during Emergency Shutdown (ESD) or Fire \u0026amp; Gas (FGS) events.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOption Specification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e-F\u003c\/td\u003e\n\u003ctd\u003eHigh-capacity F-type duplexed variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eDual-redundant power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003eBasic type with no explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e220-240 V AC power supply input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eStandard system platform license configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSSC60D-F2541\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e8.5 kg to 13.0 kg (Shipping weight: 10.0 kg to 15.0 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e482.6 mm x 266 mm x 88.1 mm (19-inch rack unit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e200-290 VA for AC models (320 W max load \/ 5.5-7.0 A for DC models)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Integrity Level\u003c\/td\u003e\n\u003ctd\u003eSIL3 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArchitecture\u003c\/td\u003e\n\u003ctd\u003eDual-redundant CPUs with ECC-protected RAM and battery backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Interfaces\u003c\/td\u003e\n\u003ctd\u003eDual Vnet\/IP (100 Mbps full duplex, RJ45) and dual ESB bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogic Execution Cycle\u003c\/td\u003e\n\u003ctd\u003e100 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Expansion Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 8 modules per SCU; up to 110 modules across 13 node units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP66 front panel protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSIL3 Certification \u0026amp; Fail-Safe State Execution\u003c\/h3\u003e\n\u003cp\u003eThe SSC60D-F2541 utilizes a redundant 2oo3 internal processor voting structure and dual communication channels to comply with SIL3 safety loop standards. Galvanic isolation barriers protect internal microprocessors from field wiring fault transients. Integrated online diagnostic routines continually verify memory matrix integrity and peripheral logic paths; if an unrecoverable hardware fault occurs, the module forces system outputs into a predefined fail-safe shutdown state.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the dual Vnet\/IP network interface execute fault tolerance on the SSC60D-F2541?\u003c\/p\u003e\n\u003cp\u003eA: The control unit runs simultaneous communication over dual redundant 100 Mbps Ethernet buses (RJ45 CAT5e), seamlessly shifting control traffic to the secondary bus if a cable or port failure occurs.\u003c\/p\u003e\n\u003cp\u003eQ: What power input ranges does the SSC60D-F2541 support?\u003c\/p\u003e\n\u003cp\u003eA: Depending on the specific suffix selection, the unit accommodates dual 100-120 V AC, 220-240 V AC, or dual 24 V DC redundant power inputs.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the SSC60D-F2541 horizontally into a standard 19-inch cabinet frame within the Safety Control Station enclosure. Secure the chassis with four front panel mounting screws to establish physical stability and earth ground grounding through the rack frame.\u003c\/p\u003e\n\u003cp\u003eConnect dual independent primary power lines to the rear AC\/DC input terminals to ensure power supply redundancy. Plug category 5e (or higher) Ethernet cables into the primary and secondary Vnet\/IP ports. Ensure a dedicated single-point earth grounding strap is fastened to the chassis ground terminal to mitigate electromagnetic interference and maintain SIL3 system compliance.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43831944151130,"sku":"SSC60D-F2541","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/410_2ac9e5f2-c775-4786-bac3-84b4a9ae4fc8.jpg?v=1786500999","url":"https:\/\/www.spareoil.com\/products\/yokogawa-ssc60d-f2541-prosafe-rs-sil3-duplexed-safety-control-unit","provider":"SpareOil Automation","version":"1.0","type":"link"}