{"product_id":"yokogawa-ycb301-c600-centum-vp-esb-bus-interface-cable","title":"YOKOGAWA YCB301-C600 CENTUM VP ESB Bus Interface Cable","description":"\u003ch2\u003eYOKOGAWA YCB301-C600 ESB Bus Cable\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-speed signal transmission within CENTUM VP distributed control systems, the \u003cstrong\u003eYOKOGAWA YCB301-C600\u003c\/strong\u003e (\u003cstrong\u003eYCB301-C600\u003c\/strong\u003e Control Bus Interface Cable) provides direct physical and electrical execution of deterministic data exchange between Field Control Units and I\/O node units.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eYCB301-C600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.24 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e600 mm (Length)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial-grade ratings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive (Bus powered)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eShielded twisted-pair ESB bus cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e9-pin D-sub\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Speed\u003c\/td\u003e\n\u003ctd\u003e128 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and DCS Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe YCB301-C600 maintains data integrity across the ESB bus by utilizing a shielded twisted-pair construction, which is required to mitigate electromagnetic interference in high-noise industrial environments. The cable provides robust physical connectivity between the EC401\/EB511 bus modules and remote I\/O node units, ensuring that the 128 Mbps throughput remains stable. Strict channel-to-channel isolation is preserved through the D-sub connector interface, preventing signal crosstalk that could otherwise degrade the deterministic timing of the DCS control cycle. Proper routing of this cable within the cabinet ensures that communication latency stays within the prescribed limits for CENTUM VP architectures.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the YCB301-C600 compatible with longer transmission distances?\u003c\/p\u003e\n\u003cp\u003eA: No, the YCB301-C600 is specifically rated for a maximum transmission distance of 10 m when utilized as an ESB bus interface. Exceeding this length will cause signal attenuation and packet loss, necessitating the use of optical ESB bus extenders for remote node connectivity.\u003c\/p\u003e\n\u003cp\u003eQ: Does the cable support hot-plugging during active DCS operation?\u003c\/p\u003e\n\u003cp\u003eA: While the ESB bus architecture is designed for high availability, hot-plugging the YCB301-C600 while the control station is powered is not recommended. Disconnecting or connecting bus cables while the processor is active can trigger transient faults or communication error logs in the CENTUM VP system.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInspect the 9-pin D-sub connectors for bent pins or debris before termination to ensure a secure physical connection.\u003c\/li\u003e\n\u003cli\u003eRoute the cable through designated signal cable trays, maintaining physical separation from high-voltage AC power lines to avoid induced interference.\u003c\/li\u003e\n\u003cli\u003eTighten the connector thumb screws fully to ensure proper chassis grounding of the cable shield.\u003c\/li\u003e\n\u003cli\u003eEnsure the cable maintains a minimum bend radius according to standard industrial cabling practices to prevent inner conductor strain or shielding damage.\u003c\/li\u003e\n\u003cli\u003eVerify the communication status on the CENTUM VP engineering station after installation to confirm that the node units are correctly addressed and synchronized.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":43577324601434,"sku":"YCB301-C600","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/426._64055773-e9ca-4b74-9a74-fd04ae8572c6.jpg?v=1782885909","url":"https:\/\/www.spareoil.com\/products\/yokogawa-ycb301-c600-centum-vp-esb-bus-interface-cable","provider":"SpareOil Automation","version":"1.0","type":"link"}