{"product_id":"z-7128-6217-c5-iti-hima-brand-new-safety-cable-plug","title":"Z 7128\/6217\/C5\/ITI HIMA Brand New Safety Cable Plug","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe HIMA Z 7128\/6217\/C5\/ITI (Model Reference: Z7128) functions as a specialized, pre-wired cable plug assembly engineered to interface directly with high-integrity I\/O modules, such as the F6217 8-channel analog input module, within HIMA HIMax and HIMatrix safety-instrumented platforms. This critical connectivity hardware comes integrated with a heavy-duty, 5-meter instrument cable that routes discrete or analog field signals while simultaneously carrying safe, regulated power to downstream transmitters. Plant engineers deploy this pre-assembled connector to bridge the gap between field infrastructure and safety controllers, ensuring reliable signal transmission that satisfies strict functional safety demands.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHIMA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eZ 7128\/6217\/C5\/ITI\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAlternate Identifier\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eZ7128\/6217\/C5\/ITI\/R2 C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eComponent Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCable Plug pre-wired with transmitter supply cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 meters (16.4 feet) continuous run\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHIMA HIMax \/ HIMatrix control racks (e.g., F6217 Module)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunctional Application\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCaptures field instrument loops and delivers transmitter power\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Distribution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated 24 VDC transmitter supply lines\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannel Capacity Alignment\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCoordinates with multi-channel (up to 8-channel) configurations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Compliance Standard\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCertified for IEC 61508 and IEC 61511 SIL 3 environments\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Assembly Shipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg (4.41 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Thermal Limits\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to +60 degrees Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature Window\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to +70 degrees Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEstimated Factory Lead Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 to 10 Weeks\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProcurement Status\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New and Original in Factory Packing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFactory Warranty Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 Months from purchase date\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003ch3\u003ePre-Wired 5-Meter Harness Eliminates Field Termination Errors\u003c\/h3\u003e\n\u003cp\u003eField-terminating multi-conductor cables inside cramped marshalling panels often introduces wiring mistakes, poor crimps, and loose wire strands that lead to intermittent signal loss. The Z 7128\/6217\/C5\/ITI eliminates this pain point by providing a factory-molded, pre-wired 5-meter plug assembly. This ready-to-install design allows technicians to drop the cable directly into standard wire trays and snap the plug onto the I\/O rack instantly, cutting installation labor costs and preventing wiring cross-connections that could jeopardize the system's safety integrity.\u003c\/p\u003e\n\u003ch3\u003eIntegrated Transmitter Power Corridors Clean Up Cabinet Footprints\u003c\/h3\u003e\n\u003cp\u003eTraditional safety system layouts require independent, external terminal distribution strips and separate fuses to supply loop power to field transmitters. This HIMA cable plug assembly embeds dedicated transmitter supply lines directly within its 5-meter shielded trunk. By feeding clean 24 VDC power out to field sensors through the primary signal connector, the Z7128 removes the need for auxiliary power distribution blocks, saving physical rail space inside execution cabinets and reducing potential points of hardware failure.\u003c\/p\u003e\n\u003ch3\u003eRobust Ground Shielding Shrugs Off High-Voltage EMI Transients\u003c\/h3\u003e\n\u003cp\u003eIndustrial processing environments contain heavy electromagnetic interference (EMI) generated by massive variable frequency drives, heavy-duty switchgear, and adjacent power conduits. The cable assembly bound to the Z 7128\/6217\/C5\/ITI utilizes high-density, comprehensive braided shielding that encapsulates the internal data lines. This protective layer repels induced electrical noise and common-mode voltage spikes, ensuring that pure, uncorrupted analog or discrete signals travel from the field transmitter to the safety controller to prevent nuisance trips or delayed emergency shutdowns.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHow does this pre-wired cable plug assist in maintaining a plant's SIL 3 safety compliance rating?\u003c\/p\u003e\n\u003cp\u003eThe Z 7128\/6217\/C5\/ITI undergoes rigorous factory testing to verify insulation resistance, cross-talk dampening, and continuity before sealing. Using this original HIMA factory-certified connection method removes the random hardware failure risks associated with manual field-built assemblies, ensuring that the critical communication path between your field loops and the safety processor matches the exact engineering specifications required to uphold your overall IEC 61508 SIL 3 validation loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan a maintenance technician modify or trim the 5-meter cable if it is too long for the cabinet run?\u003c\/p\u003e\n\u003cp\u003eWhile technicians can physically shorten the raw wire end of the 5-meter cable to land cleanly on marshalling terminal strips, they must exercise extreme care. You must strip back the inner shielding layer carefully and re-terminate the ground connections precisely to preserve the assembly's built-in noise immunity. Never modify or cut the molded plug housing that docks directly into the HIMA safety card.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs this cable plug assembly hot-swappable during active plant operations?\u003c\/p\u003e\n\u003cp\u003eYes. If your underlying HIMA I\/O module configuration supports hot-swapping and active dual-channel redundancy, you can disconnect and replace this cable plug assembly without shutting down the master controller or interrupting the remaining active safety sub-systems. Always verify that your active process conditions allow for a temporary channel isolation before disconnecting any running instrument loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":43399368179802,"sku":"Z7128","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/5957\/0778\/files\/240._eb61009f-f5ba-4cd7-8ef1-ec510305ce5d.jpg?v=1779325130","url":"https:\/\/www.spareoil.com\/products\/z-7128-6217-c5-iti-hima-brand-new-safety-cable-plug","provider":"SpareOil Automation","version":"1.0","type":"link"}