The 1769-IQ6XOW4 is a hybrid digital input and relay output module for Allen Bradley CompactLogix and MicroLogix 1500 systems. Combining 6 DC input points with 4 AC/DC relay outputs, this compact module saves cabinet space while providing flexible signal sensing and load switching. Integrated optical isolation ensures reliable operation in electrically harsh industrial environments.
| Feature | Specification |
|---|---|
| Catalog Number | 1769-IQ6XOW4 |
| Input Channels | 6 × 24V DC sink/source |
| Output Channels | 4 × AC/DC normally open relay outputs |
| Input Voltage Range | 10–30V DC |
| Output Voltage Range | 5–265V AC / 5–125V DC |
| Continuous Current per Output | 2.0 A |
| Response Time | Inputs: 8 ms; Relay outputs: 10 ms |
| Backplane Current Draw | 105 mA @ 5.1V DC; 45 mA @ 24V DC |
| Isolation Voltage | 2650V DC tested for 1 second |
| Power Dissipation | 2.8 Watts (max) |
| Terminal Block | Removable 1769-RTBN18 |
| Power Supply Distance Rating | 8 modules |
| Slot Width | 1 slot (35 mm) |
| Operating Temperature | 0–60 °C |
Hybrid Design: Combines digital inputs and relay outputs in a single compact module.
Flexible Inputs: Supports both sink (NPN) and source (PNP) wiring.
Relay Outputs: AC/DC loads up to 2 A per point with normally open contacts.
Electrical Protection: Optical isolation safeguards the backplane from voltage spikes.
Easy Maintenance: Removable terminal block simplifies wiring and replacement.
Material handling systems
HVAC control panels
Small-scale machine automation
Motor starters, solenoids, and signal monitoring
Q: Does this module require a separate power supply?
A: No, it draws logic-side power from the 1769 backplane. Field devices must be powered by an external 24V DC or AC source.
Q: Can the inputs handle both NPN and PNP sensors?
A: Yes, the 1769-IQ6XOW4 supports bipolar inputs configurable for either sink or source wiring.
Q: Is it compatible with MicroLogix controllers?
A: Yes, it works with both MicroLogix 1500 and 1769 CompactLogix systems.