100 % original. Más de 100 000 piezas en stock. Listas para enviar.

The Siemens 6GK7443-1EX11-0XE0 is a high-performance communications processor designed for the Simatic S7-400 automation system. This CP 443-1 module facilitates robust network connectivity, acting as a bridge between the PLC and industrial Ethernet environments. It supports standard Ethernet protocols and advanced diagnostic capabilities, ensuring reliable data exchange in demanding industrial applications.

Features

  • Integrated 2-port 10/100 Mbit/s IE switch with RJ45 interfaces.
  • Supports multiple communication protocols including ISO, TCP, and UDP.
  • Functions as a PROFINET IO controller for distributed I/O management.
  • Enables S7 communication and Open communication (SEND/RECEIVE).
  • Supports S7 routing and IP configuration via DHCP or block-based methods.
  • Includes IP Access Control List (ACL) for enhanced network security.
  • Provides time synchronization and extended web-based diagnostics.
  • Supports Fast Startup and PROFIenergy functionality for optimized energy management.

Technical Specifications

Product Model 6GK7443-1EX11-0XE0
Manufacturer Siemens
Interface Speed 10/100 Mbit/s
Operating Temperature 0 to 60 degC
Storage Temperature -40 to 70 degC
Weight 0.38 kg

Installation Guidelines

  • Ensure the PLC rack is powered down before inserting or removing the communications processor to prevent electrical damage.
  • Verify that the module is securely seated in the designated S7-400 slot and locked into position.
  • Use shielded Ethernet cabling to minimize EMI interference in high-noise industrial environments.
  • Adhere to proper grounding practices for the S7-400 backplane to ensure signal integrity.
  • Maintain adequate airflow around the controller rack to keep operating temperatures within the specified 0-60 degC range.
  • Handle the module using ESD-safe procedures to protect sensitive internal circuitry.

FAQ

What is the primary function of the 6GK7443-1EX11-0XE0?
This module is a communications processor (CP 443-1) used to connect S7-400 PLCs to Industrial Ethernet networks, handling data transfer, PROFINET IO control, and S7 communication.

Does this module support PROFIenergy?
Yes, this model includes support for PROFIenergy, allowing for efficient power management of connected devices.

Can I configure the IP address via DHCP?
Yes, the module supports IP configuration through both DHCP and block-based methods.

¿Qué dicen nuestros clientes sobre nosotros?