The Yokogawa EC402-50 S1, also cataloged as the EC402 ESB Bus Coupler Module, operates as a dedicated hardware component for high-speed bus communication execution within CENTUM VP and ProSafe-RS systems. The unit links system racks over dual redundant communication paths, facilitating continuous network transfers across distributed architecture backplanes. Featuring a standard non-explosion protection profile and backward compatibility for EC402-01 units, the module establishes deterministic physical links for DCS signal processing.
| Parameter | Specification |
|---|---|
| Model | EC402-50 S1 |
| Brand | Yokogawa |
| Origin | Japan |
| Weight | 0.35 - 0.40 kg (2.0 kg shipping weight) |
| Dimensions | Standard Yokogawa I/O slot footprint |
| Operating Temp | -20 to 60 deg C |
| Power Consumption | ~400 mA at 5 VDC (backplane power) |
| Protocols | Vnet/IP, Ethernet TCP/IP, ESB Bus |
| Communication Ports | Dual redundant Ethernet ports (RJ-45) |
| Data Transfer Rate | 100 Mbps full duplex |
| Operating Humidity | 10 to 95% RH (non-condensing) |
| Isolation Voltage | 1500 VAC between communication paths and logic for 1 minute |
Yokogawa DCS networks require galvanic isolation to protect internal backplane processing logic from field transmission noise and earth loops. The EC402-50 S1 incorporates 1500 VAC dielectric isolation between external communication interfaces and internal system electronics. Operating alongside Vnet/IP or 4-20 mA HART loop subnetworks, this isolation barrier prevents noise propagation across redundant field bus branches and stabilizes deterministic control communications.
Q: Can the EC402-50 S1 serve as a direct functional replacement for older EC402-01 modules? A: Yes, the EC402-50 model code represents the direct functional replacement for legacy EC402-01 ESB Bus Coupler Modules.
Q: How does the module handle communication failure on an active network port? A: The hardware utilizes dual redundant ports (RJ-45) to automatically route real-time data across the backup communication path without interrupting system logic execution.
Q: What power source supplies the electrical operating requirements of the module? A: The module draws power directly from the 5 VDC system backplane bus, consuming approximately 400 mA during standard operation.
Nuestra línea de producción se paró debido a un monitor Bently Nevada defectuoso. Lo encontramos en stock aquí y lo enviaron por DHL de inmediato. Volvió a funcionar en 48 horas, lo que realmente salvó nuestra planta.
Encontrar módulos nuevos y originales es fundamental para nuestra seguridad. Este equipo entrega componentes de fábrica con certificación completa. Su compromiso de vender únicamente productos nuevos los convierte en nuestro socio de mayor confianza.
Llevamos dos años abasteciendo aquí piezas de Honeywell y Schneider. Todos nuestros envíos llegan perfectamente embalados, con los precintos originales de fábrica intactos. Ofrecemos una comunicación clara y los mejores plazos de entrega del sector.