100 % original. Más de 100 000 piezas en stock. Listas para enviar.

  • es

Yokogawa ADV151-E60 S2 Digital Input Module

Configured for discrete signal acquisition in CENTUM VP and CS 3000 control systems, the Yokogawa ADV151-E60 S2 (ADV151 Digital Input Module) provides direct physical/electrical execution.

Suffix Breakdown & Model Matrix

  • Base Model (ADV151): Digital Input Module featuring 32 isolated channels operating at 24 VDC nominal input voltage.
  • Function Suffix (-E): Equips Sequence of Events (SOE) timestamp capture capability for high-speed signal transient logging.
  • Protection Suffix (6): Features front-panel LED status displays with no explosion-proof protection rating.
  • Type Suffix (0): Indicates the basic hardware module footprint.
  • Style Code (S2): Hardware circuit revision level denoting functional design compatibility and updated firmware baseline execution.

Hardware Specifications

Parameter Specification
Model ADV151-E60 S2
Brand Yokogawa
Origin Japan
Weight 0.63 kg
Dimensions 5.1 x 25.4 x 11.4 cm
Operating Temp -20 to 70 deg C
Power Consumption 200 mA max at 5 VDC, 30 mA max at 24 VDC
Input Channels 32 channels, current sourcing / dry contact
Rated Input Voltage 24 VDC (18 to 26.4 VDC allowable range)
Isolation Withstand 1500 VAC between field signals and system logic for 1 minute
Response Time <= 5 ms ON/OFF transition time

4-20 mA HART Loop & Fieldbus Connectivity Dynamics

The ADV151-E60 S2 module interfaces discrete field devices such as valve limit switches and relay contacts while operating alongside 4-20 mA HART analog I/O modules across CENTUM node racks. Internal optical isolation barriers rated at 1500 VAC decouple signal ground loops, ensuring high-frequency switching transients on field wiring do not inject noise into adjacent 4-20 mA HART instrumentation or process bus communication channels. Integrated SOE firmware registers channel state changes with millisecond-level precision directly at the node level.

Frequently Asked Questions

Q: Can the ADV151-E60 S2 module undergo hot-swapping during active control operations?

A: Yes, online replacement is supported when the module resides in a configured node rack, allowing live swap-out without disturbing adjacent backplane processing.

Q: What are the input voltage threshold limits for ON and OFF state recognition?

A: The input circuitry interprets voltages greater than or equal to 15 VDC as an ON state and voltages less than or equal to 5 VDC as an OFF state.

Q: Is the ADV151-E60 S2 backward compatible with older ADV151-E10 module installations?

A: Yes, part number ADV151-E60 serves as a direct functional replacement for the previous ADV151-E10 hardware revision.

Field Installation Guidelines

  1. Power Supply Verification: Ensure field-side 24 VDC power sources operate within the 18 to 26.4 VDC voltage envelope before energizing input loops.
  2. Ground Shielding: Terminate overall field cable shields at the dedicated cabinet ground bar to maintain signal integrity and surge protection limits.
  3. Rack Alignment: Slide the module squarely into the node slot guide channels until the backplane edge connector fully seats, then hand-tighten the retaining screws.
  4. Cable Routing: Route digital input field wiring away from high-voltage AC supply cables and variable frequency drive outputs to prevent capacitive noise coupling.