100 % original. Más de 100 000 piezas en stock. Listas para enviar.

  • es

Yokogawa ADV151-E63 S2 Digital Input Modules

Configured for high-density field signal processing in CENTUM VP platforms, the Yokogawa ADV151-E63 S2 (ADV151 Digital Input Module) provides direct physical/electrical execution. The hardware routes discrete field voltages and process analog signals across isolated channels to execute real-time status acquisition for system logic execution. Incorporating ISA Standard G3 conformal coating and standard backplane connectivity, the module processes field inputs while providing 1500 VAC galvanic isolation.

Hardware Specifications

Parameter Specification
Model ADV151-E63 S2
Brand Yokogawa
Origin Japan
Weight 0.45 - 0.63 kg (3.00 lbs shipping weight)
Dimensions 51 mm x 254 mm x 114 mm
Operating Temp -20 to 70 deg C (G3 standard compliant)
Power Consumption 400 mA (5 VDC), 200 mA (24 VDC)
Channel Capacity 16 / 32 channels (configuration dependent)
Input Signal Types Voltage (+/-10 VDC), Current (4-20 mA DC)
Input Resistance 250 Ohm (current), >= 1 MOhm (voltage)
Signal Accuracy +/-0.1% of full scale
Signal Resolution 12 to 16 bits
Response Time <= 100 ms
Isolation Voltage 1500 VAC between input terminals and system logic for 1 minute

4-20 mA HART Loop Protocol and Channel Isolation

Yokogawa DCS platforms rely on strict isolation barriers to prevent field transients from impacting central system processors. The ADV151-E63 S2 incorporates 1500 VAC withstand isolation between field input terminals and internal backplane logic bus lines. When integrated with 4-20 mA loops or HART transmitter networks, this channel-to-channel isolation mitigates common-mode ground loop noise and maintains signal integrity across analog monitoring loops.

Frequently Asked Questions

Q: What isolation rating protects system logic from field-side voltage transients? A: The module provides 1500 VAC isolation for 1 minute between input terminals and the backplane logic interface.

Q: Does the module support active redundant configurations in live systems? A: Yes, the unit supports dual-redundant operation and online hot-swapping to enable module replacement without interrupting continuous process monitoring.

Q: What input impedance levels apply when connecting current or voltage devices? A: Current loop connections exhibit a 250 Ohm input resistance, while voltage input configurations present a high input impedance of >= 1 MOhm.

Field Installation Guidelines

  1. Power down backplane rack slots or verify active redundant module operation prior to inserting or removing hardware.
  2. Verify mechanical keying on the rack slot interface to ensure exact pin alignment and prevent connector terminal damage.
  3. Terminate signal cables or cable adapters using proper terminal tightening torque to ensure secure electrical contact.
  4. Route 4-20 mA signal wires through dedicated low-voltage instrument trays separated from high-voltage AC conductors.
  5. Ground signal cable drain shields at a single point on the cabinet protective earthing bar to eliminate circulating ground loops.

¿Qué dicen nuestros clientes sobre nosotros?