100 % original. Más de 100 000 piezas en stock. Listas para enviar.

  • es

Yokogawa ALE111-S01 Ethernet Communication Module

Configured for high-speed data exchange in CENTUM VP platforms, the Yokogawa ALE111-S01 (ALE111-S01 Ethernet Communication Module) provides direct physical execution of I/O subsystem and Field Control Station (FCS) communication.

Suffix Breakdown & Model Matrix

Suffix Description
ALE111 Base Model: Ethernet Communication Module
-S Standard Type
01 With ISA Standard G3 compliance

Hardware Specifications

Parameter Specification
Model ALE111-S01
Brand Yokogawa
Origin Japan
Weight 0.3 kg
Dimensions 120 x 90 x 30 mm
Operating Temp -10 deg C to +55 deg C
Power Consumption 0.3 A (typical) at 24 VDC
System Compatibility CENTUM VP / CS 3000
Communication Vnet/IP, RS-422/485

Process Control and Channel-to-Channel Isolation

The ALE111-S01 serves as the primary gateway for data traffic between field I/O subsystems and the main control processor. Yokogawa engineers incorporate optical and electrical isolation within the module to decouple the communication bus from the host system. Consequently, this design prevents ground potential differences and common-mode transients from disrupting data packets. Furthermore, the module supports dual-redundant installation, which allows operators to maintain continuous system control even if a primary communication link fails.

Frequently Asked Questions

Q: Does the module support hot-swapping during active system operation?

A: You must ensure the I/O rack power remains stable, but the module architecture allows for extraction while the system is energized. However, you should follow the specific DCS software commands to take the node offline before removal to prevent communication errors.

Q: How do operators verify the redundant link status?

A: The front panel status LEDs provide visual confirmation of the primary and secondary communication links. If a synchronization fault occurs, the module logs a diagnostic alarm within the CENTUM VP engineering station.

Field Installation Guidelines

  1. Mounting: Insert the ALE111-S01 into the dedicated slot on the I/O base. You must engage the locking screws to ensure the module maintains firm contact with the backplane connectors.
  2. Wiring: Connect the Ethernet or serial cables to the designated ports. Use high-quality shielded cabling to mitigate EMI, as noise levels in control rooms directly impact packet latency.
  3. Grounding: Terminate the cable shields to the cabinet ground bar. This connection shunts induced electrical noise away from the internal logic circuits.
  4. Validation: Initiate the diagnostic test via the control station software to confirm the module handshake with the FCS. Observe the indicator lights to ensure both redundant channels show active, steady states.

¿Qué dicen nuestros clientes sobre nosotros?

Translation missing: es.general.search.loading