The 1769-SM2 is a high-performance serial communication module for bridging 1769-based controllers with PowerFlex AC drives. Supporting both Drive Serial Interface (DSI) and Modbus RTU protocols, it enables control of up to five drives per module in multi-drive mode. This module is essential for machine builders using MicroLogix 1500 or CompactLogix systems who require drive parameter monitoring and control over a serial network without occupying additional network nodes.
| Item | Specification |
|---|---|
| Module Type | 1769-SM2 Communication Module |
| Protocol Support | Drive Serial Interface (DSI), Modbus RTU |
| Drive Compatibility | PowerFlex 4-class (4, 40, 400), PowerFlex 7-class (via 20-HIM-H-RS485-HVAC adapter) |
| Backplane Current Draw | 350 mA @ 5.1 V DC; 0 mA @ 24 V DC |
| Power Supply Distance Rating | 4 slots from 1769 power supply |
| DSI Communication Speed | 19.2 kbps fixed |
| Modbus RTU Speeds | 300–38400 bps |
| Operating Modes | Single-drive or Multi-drive (up to 5 drives) |
| Channel Configuration | 3 independent serial channels |
| Operating Temperature | -10 to 50 °C (14 to 122 °F) |
| Weight | 0.17 kg |
The 1769-SM2 converts Logix backplane data into serial packets for DSI or Modbus RTU communication. In multi-drive mode, it reduces hardware footprint by consolidating multiple PowerFlex units into a single slot.
MicroLogix 1500: Functions as a local expansion module.
CompactLogix: Usable in local chassis or remote 1769 I/O assemblies.
Parameter Access: Full access to drive parameters for real-time monitoring and configuration via RSLogix 500 or Studio 5000.
Place the module within four slots of the system power supply to maintain 5 V DC bus integrity.
Use shielded twisted-pair cabling for all DSI and Modbus connections to minimize EMI in motor control environments.
Can the 1769-SM2 control PowerFlex 525 drives?
Yes, it can communicate via DSI, though modern applications typically use 1769-LxxER controllers' Ethernet ports for improved performance.
Does this module support Modbus TCP?
No. The 1769-SM2 is serial-only. For Modbus TCP, use a CompactLogix 5370 Ethernet port with Open Sockets or a third-party gateway.