The Bently Nevada 330104-10-16-10-02-00 serves as the primary 330104 Proximity Probe utilized to execute non-contacting displacement and vibration measurements across 3300 XL Proximity Transducer System platforms.
| Parameter | Specification |
|---|---|
| Model | 330104-10-16-10-02-00 |
| Brand | Bently Nevada |
| Origin | U.S.A. |
| Weight | 0.250 kg nominal |
| Dimensions | 8 mm probe tip diameter, 160 mm overall case length, 1.0 meter total cable length |
| Operating Temp | -51 deg C to +177 deg C |
| Power Consumption | -17.5 VDC to -26 VDC, maximum 12 mA (without barriers) |
| Measurement Range | 2 mm (80 mils) linear range |
| Output Sensitivity | 7.87 V/mm (200 mV/mil) |
| Output Resistance | 50 Ohm nominal |
| Probe Tip Material | Polyphenylene sulfide (PPS) |
| Cable Type | 75 Ohm coaxial, fluoroethylene propylene (FEP) insulated |
| Threaded Length | 60 mm |
The 330104-10-16-10-02-00 proximity probe utilizes a high-frequency RF carrier signal to complete eddy-current probe scaling against a conductive shaft target surface. When driven via a matching 3300 XL Proximitor Sensor, physical changes in distance translate directly to the factory-calibrated 7.87 V/mm voltage loop output. Proper installation requires precise gap voltage validation to anchor the sensor within its 2 mm linear envelope. Field technicians must manipulate the physical probe location relative to the shaft surface until the static voltage stabilizes at the defined -10 VDC targets, denoting the physical midpoint of calibration. This baseline verification is necessary to accurately analyze complex rotor dynamics, while structural isolation inside the sensor path provides cross-talk suppression between concurrent radial measurements on the machine.
Q: How does introducing zener intrinsic safety barriers into the loop alter the power parameters and measurement range?
A: Installing barriers reduces the loop supply potential delivered to the driver circuit. Under barrier operations at -23 VDC to -26 VDC, the system exhibits a slightly reduced linear range compared to the unbarrier-protected 2 mm baseline specification.
Q: Can this 75 Ohm coaxial cable be modified or repaired by removing the ClickLoc connector in the field?
A: No. Splicing or reshaping the FEP-insulated coaxial line modifies the total electrical system length and nominal impedance. This introduces tracking errors into the factory eddy-current probe scaling and shifts the operational gap voltage calibration away from standard specifications.
Nuestra línea de producción se paró debido a un monitor Bently Nevada defectuoso. Lo encontramos en stock aquí y lo enviaron por DHL de inmediato. Volvió a funcionar en 48 horas, lo que realmente salvó nuestra planta.
Encontrar módulos nuevos y originales es fundamental para nuestra seguridad. Este equipo entrega componentes de fábrica con certificación completa. Su compromiso de vender únicamente productos nuevos los convierte en nuestro socio de mayor confianza.
Llevamos dos años abasteciendo aquí piezas de Honeywell y Schneider. Todos nuestros envíos llegan perfectamente embalados, con los precintos originales de fábrica intactos. Ofrecemos una comunicación clara y los mejores plazos de entrega del sector.