100 % original. Más de 100 000 piezas en stock. Listas para enviar.

  • es

Description

The Bently Nevada 3500/42M 176449-02 is a high-performance Proximitor/Seismic Monitor module designed for the 3500 Machinery Protection System. This 4-channel module provides continuous monitoring of vibration, position, and seismic measurements by accepting signals from proximity probes, Velomitor sensors, accelerometers, and other compatible transducers. It conditions incoming signals, performs real-time measurement calculations, and compares results against user-configurable alarm setpoints to support critical machinery protection and condition monitoring programs.

Features

  • 4-channel monitoring capability for high-density rack configurations.
  • Supports diverse measurement types: radial vibration, shaft absolute vibration, thrust position, differential expansion, velocity, acceleration, and eccentricity.
  • Independent channel configuration via 3500 Rack Configuration Software.
  • Internal safety barriers (indicated by -02 suffix) for hazardous area isolation.
  • Buffered outputs on the front panel for portable vibration analyzer connection without signal interruption.
  • Programmable alarm setpoints (Alert and Danger) and time delays to prevent false trips.

Applications

  • Power Generation: Monitoring stability of large steam and gas turbines and generators.
  • Oil & Gas: Protection for high-pressure compressors, pumps, and critical rotating assets in refineries and offshore platforms.
  • Manufacturing: Asset protection for heavy industrial rotating machinery.

Technical Specifications

Parameter Specification
Model 3500/42M 176449-02
Channels 4
Operating Temperature -30 degC to +65 degC
Storage Temperature -40 degC to +85 degC
Humidity 95% Non-condensing
Power Consumption 7.7 Watts (typical)
Transducer Power Supply -24 Vdc
Output Impedance 550 Ohm

Installation Guidelines

  • Ensure the 3500 rack is powered down before inserting or removing the module to prevent electrical damage.
  • The module must be seated correctly in the designated rack slot; ensure the backplane connector is fully engaged.
  • Use shielded cabling for all transducer inputs to minimize EMI/RFI interference in industrial environments.
  • Channel pairs (1/2 and 3/4) must be configured with compatible monitoring functions.
  • Maintain proper ventilation within the cabinet to stay within the specified operating temperature range.

FAQ

What does the -02 suffix indicate?
The -02 suffix denotes that the module is equipped with an I/O module featuring internal safety barriers, suitable for isolating signals in hazardous environments.

Can I use this for seismic monitoring?
Yes, the 3500/42M is specifically designed to accept inputs from seismic transducers to detect and analyze ground or housing vibrations.

How do I configure the alarm setpoints?
Alarm setpoints and time delays (1 to 60 seconds) are programmed using the Bently Nevada 3500 Rack Configuration Software.