100 % original. Más de 100 000 piezas en stock. Listas para enviar.

  • es

The Bently Nevada 330101-00-55-10-02-05, also cataloged as the 330101 8 mm Proximity Probe, operates as a dedicated hardware component for non-contacting vibration and position measurement within rotor dynamics monitoring systems.

Suffix Breakdown & Model Matrix

Option Description
330101 3300 XL 8 mm Probe, 3/8-24 UNF thread, without armor
00 Unthreaded length: 0.0 in
55 Overall case length: 5.5 in
10 Total length: 1.0 meter
02 Miniature coaxial ClickLoc connector, standard cable
05 Agency approval: CSA, ATEX, IECEx

Hardware Specifications

Parameter Specification
Model 330101-00-55-10-02-05
Brand Bently Nevada
Origin USA
Weight 0.323 kg
Dimensions 5.5 in case length
Operating Temp -51 deg C to +177 deg C
Power Consumption Passive (Powered by Proximitor)
Probe Tip Material Polyphenylene Sulfide (PPS)
Case Material AISI 303/304 Stainless Steel

Mechanical Monitoring and Rotor Dynamics

The 330101 series utilizes an eddy-current principle to detect the proximity of a conductive target. Proper scaling is required to maintain the standard 7.87 V/mm (200 mV/mil) output sensitivity provided by the matching 3300 XL Proximitor sensor. During installation, the gap voltage must be validated against a -10 VDC target at the mid-linear range to ensure linear response. Signal integrity depends on minimizing cross-talk between adjacent probes and ensuring the target material surface conforms to material correction specifications to maintain accurate rotor dynamic vibration data.

Frequently Asked Questions

Q: Can the 1.0 meter cable length be extended?

A: The total system length (probe + extension cable) must be matched to the Proximitor sensor calibration (typically 5 m or 9 m). If the probe cable is 1.0 m, an appropriate 4.0 m extension cable is required to reach a 5.0 m system length.

Q: What is the requirement for the thread engagement during installation?

A: A minimum of 4 to 5 threads of engagement is required for the probe housing to ensure mechanical stability and proper grounding in the machinery casing.

Field Installation Guidelines

  1. Ensure the probe mounting bracket is rigid to minimize resonance effects at the probe location.
  2. Verify that the total system length (probe plus extension cable) matches the Proximitor sensor calibration (5 m or 9 m).
  3. Use the provided locknut to secure the probe position; ensure the locknut is tightened to prevent loosening due to machine-induced vibration.
  4. Perform a bench-top gap verification using a calibrated micrometer to confirm the -10 VDC setpoint before full installation into the machinery.
  5. Protect the ClickLoc connector from environmental contamination by using suitable conduit or junction boxes.