Configured for backplane power distribution in VersaMax system platforms, the GE Fanuc IC200PWR102 (IC200PWR102 Power Supply Module) provides direct physical/electrical execution. The module converts AC mains input power into regulated 5 VDC and 3.3 VDC system buses to power attached CPUs, Network Interface Units (NIUs), and expansion I/O modules.
| Parameter | Specification |
|---|---|
| Model | IC200PWR102 |
| Brand | GE Fanuc |
| Origin | USA |
| Weight | 0.31 lbs (0.14 kg) |
| Dimensions | Single-slot VersaMax module footprint |
| Operating Temp | 0 deg C to 60 deg C |
| Power Consumption | 27 VA input power |
| Input Voltage Ranges | 85-132 VAC (120 VAC nominal) / 176-264 VAC (240 VAC nominal) |
| Input Frequency | 47 to 63 Hz |
| Voltage Selection | Jumper installed: 120 VAC; Jumper uninstalled: 240 VAC |
| Output Voltages | 5 VDC and 3.3 VDC |
| Maximum Output Current | 1.5 A total (up to 1.5 A @ 5 VDC, up to 1.0 A @ 3.3 VDC) |
| Holdup Time | 20 ms |
| Built-in Protection | Short circuit and overload protection |
The module executes direct power injection to the VersaMax system backplane, supplying up to 1.5 A combined current across the internal 5 VDC and 3.3 VDC buses. It operates either as the primary system power supply or as a supplemental booster supply mounted on a Power Supply Booster carrier. The unit maintains voltage regulation during momentary power losses with a 20 ms holdup time. Overload and short-circuit protection circuits continuously monitor output parameters to preserve backplane voltage integrity.
Q: How is the input voltage selection set between 120 VAC and 240 VAC on the IC200PWR102?
A: A hardware terminal jumper on the unit controls the range: installing the jumper selects 120 VAC nominal (85-132 VAC), while omitting the jumper selects 240 VAC nominal (176-264 VAC).
Q: What is the total maximum combined output current supplied to the backplane?
A: The combined total output current across both 5 VDC and 3.3 VDC rails cannot exceed 1.5 A maximum.
Q: Can the IC200PWR102 be used in expansion configurations?
A: Yes, it can serve as a primary power module or as a secondary supply when attached to a VersaMax Power Supply Booster carrier.
Nuestra línea de producción se paró debido a un monitor Bently Nevada defectuoso. Lo encontramos en stock aquí y lo enviaron por DHL de inmediato. Volvió a funcionar en 48 horas, lo que realmente salvó nuestra planta.
Encontrar módulos nuevos y originales es fundamental para nuestra seguridad. Este equipo entrega componentes de fábrica con certificación completa. Su compromiso de vender únicamente productos nuevos los convierte en nuestro socio de mayor confianza.
Llevamos dos años abasteciendo aquí piezas de Honeywell y Schneider. Todos nuestros envíos llegan perfectamente embalados, con los precintos originales de fábrica intactos. Ofrecemos una comunicación clara y los mejores plazos de entrega del sector.