The GE Fanuc IC694PWR331, also cataloged as the IC694PWR331 Expansion Power Supply, operates as a dedicated hardware component for 24 VDC voltage conversion and backplane power distribution within PACSystems RX3i platforms.

Hardware Specifications

Parameter Specification
Model IC694PWR331
Brand GE Fanuc
Origin USA / As specified on hardware label
Weight Shipping weight: 2.0 kg
Dimensions Standard single RX3i power supply slot footprint
Operating Temp 0 to 60 deg C
Power Consumption Input power source: 24 VDC
Power Capacity 30 W total high capacity output
Output Ratings 30 W @ 5 VDC; 15 W @ 24 VDC Relay; 20 W @ 24 VDC Isolated
24 VDC Output Current 0.8 A capacity
Backplane Support Remote bases only
Module Type Expansion / Remote power supply

Backplane Bus Communication Velocity and I/O Density Scaling

The IC694PWR331 delivers high-capacity DC power directly to the backplane bus of RX3i remote expansion racks, supplying up to 30 W total distributed power across internal logic circuits. By supplying 5 VDC for module bus execution alongside 24 VDC isolated and relay power outputs, the supply maintains backplane bus communication velocity and supports high I/O density scaling across populated expansion slots. Designed exclusively for remote base configurations, it isolates field disturbance potential while stabilizing logic power levels.

Frequently Asked Questions

Q: Can the IC694PWR331 power supply be installed in a primary PACSystems RX3i CPU rack?

A: No, the IC694PWR331 is designed for backplane support on remote bases only.

Q: What are the output power allocations available from the IC694PWR331?

A: The unit supplies a maximum total output of 30 W, allocated up to 30 W at 5 VDC, 15 W at 24 VDC relay power, and 20 W at 24 VDC isolated power with a 0.8 A output current capacity.

Field Installation Guidelines

  • Isolate all incoming 24 VDC power sources prior to inserting or removing the power supply module from the left-most power supply slot of the remote baseplate.
  • Connect input wiring securely to designated 24 VDC power terminals, ensuring correct polarity and proper frame ground conductor landing.
  • Maintain clear vertical ventilation channels around the module housing to allow free ambient air movement for thermal dissipation.
  • Verify that total power consumption of all populated I/O cards in the remote rack does not exceed the 30 W total output threshold of the supply.