Configured for forced air circulation in CENTUM VP and CENTUM CS system cabinets, the YOKOGAWA AIP601 S1 (AIP601 S1 Cabinet Cooling Fan Unit) provides direct thermal management for rack-mounted controllers, communication processors, and I/O modules.
| Parameter | Specification |
|---|---|
| Model | AIP601 S1 |
| Brand | YOKOGAWA |
| Origin | Japan |
| Weight | 4.5 kg |
| Dimensions | 482.6 mm x 132.5 mm x 205 mm |
| Operating Temp | 0 to 50 deg C |
| Power Consumption | 0.5 A at 24 V DC |
| Cooling Method | Forced air circulation |
| Airflow Capacity | 2.5 m3/min per fan |
The AIP601 unit operates as an active component within the Yokogawa DCS cabinet infrastructure to maintain component ambient temperatures within specified limits. The module incorporates dual-fan redundancy, ensuring sustained airflow even if a single mechanical failure occurs. By promoting consistent air movement across backplanes and processing modules, the unit prevents localized thermal buildup that often leads to intermittent bus communication errors or premature electronic component drift. Furthermore, the design supports air intake and exhaust cycles that align with standard cabinet ventilation paths, facilitating passive heat rejection through the cabinet enclosures in the CENTUM VP and CS control systems.
Q: Can the fan unit be serviced or replaced while the control cabinet remains operational?
A: Yes, the AIP601 unit allows for fan maintenance or replacement without requiring a full system shutdown, provided technicians exercise caution near internal electrical terminals during extraction.
Q: Is the AIP601 cooling fan unit capable of regulating its speed based on cabinet temperature?
A: No, this unit provides constant speed forced air circulation when energized with 24 V DC. It does not utilize thermal feedback loops to modulate airflow based on real-time cabinet temperature fluctuations.
Q: Can the unit be mounted in any orientation within the 19-inch rack?
A: The AIP601 requires horizontal mounting to ensure optimal airflow distribution and mechanical stress relief on the rack-mount brackets. Mounting in non-horizontal orientations may compromise fan bearing longevity.
Mount the unit securely into a 3U rack space within the standard 19-inch cabinet using the integrated front-panel mounting hardware. Ensure the intake and exhaust vents remain free of obstruction to maintain the rated airflow capacity. Connect the 24 V DC power supply leads to the designated terminal block, ensuring correct polarity. Maintain at least 50 mm of clearance from the rear of the unit to the back cabinet wall to facilitate unobstructed air discharge. Regularly inspect the fan inlet filters for dust accumulation, as restricted airflow increases the internal operating temperature of the DCS processors and shortens the operational lifespan of the installed I/O modules.
Nuestra línea de producción se paró debido a un monitor Bently Nevada defectuoso. Lo encontramos en stock aquí y lo enviaron por DHL de inmediato. Volvió a funcionar en 48 horas, lo que realmente salvó nuestra planta.
Encontrar módulos nuevos y originales es fundamental para nuestra seguridad. Este equipo entrega componentes de fábrica con certificación completa. Su compromiso de vender únicamente productos nuevos los convierte en nuestro socio de mayor confianza.
Llevamos dos años abasteciendo aquí piezas de Honeywell y Schneider. Todos nuestros envíos llegan perfectamente embalados, con los precintos originales de fábrica intactos. Ofrecemos una comunicación clara y los mejores plazos de entrega del sector.