100% Genuine. 100,000+ Parts in Stock. Ready to Ship.

  • en

Yokogawa CP701-S1 CENTUM VP Field Control CPU Module

Configured for direct control logic execution and real-time process signal management in CENTUM VP platforms, the Yokogawa CP701-S1 (CP701 Field Control CPU Module) provides direct physical/electrical execution across high-speed system racks.

Hardware Specifications

Parameter Specification
Model CP701-S1
Brand Yokogawa
Origin Japan
Weight 0.5 kg to 0.7 kg
Dimensions 150 mm x 25 mm x 100 mm
Operating Temp 0 deg C to 60 deg C
Power Consumption 24 V DC (redundant power supply supported)
Processor Type High-performance RISC processor
Memory 64 MB DRAM (logic execution), 128 MB flash (program/data storage)
Scan Cycle Execution Typical scan cycle <= 50 ms
Redundancy Architecture Dual-redundant CPU option (hot-standby configuration)
Communication Interfaces Vnet/IP (1 Gbps), Ethernet, RS-485
Supported Field Protocols Modbus TCP/IP, FOUNDATION Fieldbus, HART passthrough
Diagnostic Functions Built-in self-test, watchdog timer, error logging
Mounting Format System rack insertion inside Field Control Station (FCS) cabinet
System Compatibility Yokogawa CENTUM VP DCS platform exclusively
Compliance Certifications CE, UL, CSA, IEC 61508 SIL compliant

DCS Field Interface and Channel Isolation

The CP701-S1 routes real-time control algorithms through high-speed backplane channels to interface directly with remote field I/O modules. Integrated 4-20 mA HART loop protocol passthrough and FOUNDATION Fieldbus connectivity enable bidirectionally isolated field device management without secondary gateways. Channel-to-channel isolation on associated I/O racks prevents ground potential shifts from affecting CPU logic execution. Internal firmware routines support cold junction compensation (CJC) referencing across incoming thermocouple loops, maintaining process variable precision across variable rack ambient temperatures.

Frequently Asked Questions

Q: What precautions apply when configuring the dual CPU hot-standby redundancy setup?

A: Ensure both CP701-S1 modules reside in designated adjacent slots of the same CENTUM VP system rack and run identical firmware revisions. Hot-standby synchronization occurs over dedicated backplane traces to ensure bump-free control takeover upon primary CPU fault detection.

Q: How does the module handle power supply disruptions without losing operational program state?

A: The module executes non-volatile program storage via its 128 MB flash memory while 64 MB DRAM retains volatile execution data. Redundant 24 V DC power connections on the base rack prevent processor reset during a single power bus drop.

Field Installation Guidelines

Insert the CP701-S1 vertically into the designated slot of the CENTUM VP Field Control Station system rack. Press the module firmly into the backplane connector until top and bottom locking levers seat completely into the rack frame.

Connect all network interfaces using category-rated shielded cables. Ensure the cabinet earth ground connects directly to the protective earth terminal on the rack chassis using a short, heavy-gauge conductor to maintain isolation performance and reduce electromagnetic noise.

What's clients say about us

Translation missing: en.general.search.loading