The Woodward easYgen-3000, also cataloged as the Woodward easYgen-3000 Series Genset Control and Power Management System, operates as a dedicated hardware component for complete genset automation, synchronization, and load sharing within isolated or paralleled power network platforms.
| Parameter | Specification |
|---|---|
| Model | easYgen-3000 |
| Brand | Woodward |
| Origin | United States |
| Weight | 1.50 kg |
| Dimensions | 21.9 cm x 17.1 cm x 6.1 cm |
| Operating Temp | -20 to +70 deg C |
| Power Consumption | 24 VDC nominal (18-32 VDC operating range) |
| Analog Inputs | 0-20 mA, resistive (0-500 Ohm), VDO sensors |
| Analog Outputs | 0/4 to 20 mA for speed/voltage bias control |
| Power Sensing | Class I true RMS sensing |
| Interfaces | CAN, RS-232, RS-485, Ethernet |
| Protocols | CANopen, J1939, Modbus RTU, Modbus TCP |
The processing architecture evaluates real-time true RMS power sensing parameters to regulate the actuator loop feedback response. Speed and voltage bias commands are transmitted via isolated 0/4 to 20 mA analog outputs or digital communication networks directly to the governor and automatic voltage regulator (AVR). Internal PID controllers calculate slip frequency, phase matching, and kW/kVAR load sharing variables dynamically, adjusting bias outputs within millisecond execution cycles to prevent frequency deviation and mechanical stress during circuit breaker closure sequences.
Q: How does the internal logic architecture handle a failure of the primary master controller in a multi-unit network?
A: The hardware supports multi-master redundancy across the CAN network. If the designated master unit goes offline, another easYgen-3000 controller automatically assumes network command to maintain uninterrupted power management.
Q: What are the isolation and environmental protections applied to the physical interfaces of this controller?
A: All primary communication lines and I/O channels feature galvanic isolation to suppress common-mode electrical noise. The internal circuit boards are coated with a conformal compound to prevent damage from moisture and airborne industrial contaminants.
Our production line was down due to a faulty Bently Nevada monitor. We found it in stock here and they shipped it via DHL immediately. Back in operation within 48 hours—truly a lifesaver for our plant.
Finding brand new, original modules is critical for our safety. This team delivers factory-fresh components with full certification. Their commitment to only selling new products makes them our most trusted partner.
We have sourced Honeywell and Schneider parts here for two years. Every shipment arrives well-packaged with original factory seals intact. Clear communication and the best lead times in the industry.