100% Genuine. 100,000+ Parts in Stock. Ready to Ship.

  • en

Description

The Honeywell 8U-TPOXA1 is a specialized PROFIBUS Gateway IOTA module engineered for high-performance communication within industrial control environments. This module functions as a critical interface for PROFIBUS DP networks, enabling robust connectivity for supervisory systems. It is specifically designed to support both DP V0 standard messaging and DP V1 Class-2 master functionality, facilitating seamless integration with FDM (Field Device Manager) and Profidrive DSB systems in demanding industrial sectors such as power generation, chemical processing, and mining.

Features

  • PROFIBUS Integration: Supports DP V0 and DP V1 protocols for comprehensive fieldbus communication.
  • FDM Support: Enables advanced messaging capabilities via DP V1 Class-2 master functionality.
  • Hot-Swappable Design: Engineered for insertion and removal under power, allowing for maintenance without requiring a system-wide shutdown.
  • Robust Architecture: Designed for the Honeywell Series 8 IOTA (Input/Output Termination Assembly) cabinet standard.
  • Industrial Reliability: Built to withstand harsh operational environments with a wide storage temperature range.

Technical Specifications

Model 8U-TPOXA1
Operating Voltage 24 VDC
Current Consumption 430 mA
Network Protocol PROFIBUS DP (V0/V1)
Operating Temperature 0 to 60 deg C
Storage Temperature -40 to 85 deg C
Mounting Series 8 IOTA Assembly

Installation Guidelines

  • Ensure the IOTA cabinet is properly grounded prior to module installation to prevent electrostatic discharge (ESD) damage.
  • Verify that the Series 8 power system is stable at 24 VDC before seating the module into the assembly.
  • While the module supports hot-swapping, ensure that the communication cabling is securely routed and shielded to minimize EMI in high-noise industrial areas.
  • Check that all PROFIBUS network termination resistors are correctly configured at the end of the bus segments to maintain signal integrity.

FAQ

Is the 8U-TPOXA1 capable of hot-swapping? Yes, this module is designed to be inserted or removed under power, minimizing process downtime during routine maintenance.

What is the primary communication standard for this module? It supports PROFIBUS DP V0 and V1, serving as a master interface for supervisory control and FDM integration.

What is the required power supply for this module? The module operates on a 24 VDC supply with a current draw of 430 mA.