100% Genuine. 100,000+ Parts in Stock. Ready to Ship.

Description

The Schneider Electric 140CRA21220 serves as a critical remote I/O drop interface for the Modicon Quantum automation platform. This module facilitates reliable data exchange between the central processor and remote I/O racks, ensuring deterministic performance in demanding industrial environments such as petrochemical processing, power generation, and large-scale manufacturing. By utilizing a 24 VDC power supply, the unit provides high-speed communication management and robust signal integrity for distributed field devices.

Features

  • Dual coaxial communication ports for redundant S908 network connectivity.
  • Rapid failover switching (under 1 ms) to ensure continuous operation during network cable faults.
  • Front-mounted rotary switches for manual address configuration.
  • Comprehensive LED array for real-time monitoring of port synchronization and system diagnostic status.
  • Galvanic isolation between field and bus circuitry to protect internal components from electrical interference.

Applications

This interface module is engineered for use in distributed control systems where long-distance communication and high availability are required. It is commonly deployed in hazardous or high-EMI environments where secondary line redundancy is necessary to prevent costly production downtime.

Technical Specifications

Model 140CRA21220
Brand Schneider Electric
Series Modicon Quantum
Input Voltage 24 VDC (19.2-30 VDC range)
Current Consumption 650 mA
Network Protocol S908 Distributed I/O
Communication Ports 2 x Coaxial (75 Ohm F-connector)
Data Rate 1.544 Mbps
Isolation 500 VDC (1 minute)
Operating Temperature 0 to 60 deg C
Humidity 5-95% (non-condensing)

Installation Guidelines

  • Ensure the rack is powered down before inserting or removing the module to prevent electrical damage.
  • Mount the module within a standard Modicon Quantum backplane, ensuring the connector pins are fully seated.
  • Use high-quality 75 Ohm coaxial cables for network connections; ensure proper shielding and grounding to minimize EMI.
  • Verify that the address selection switches match the intended configuration in the project software before commissioning.
  • Maintain proper ventilation within the cabinet to stay within the 0-60 deg C operating temperature range.