Configured for precision vibration sensing in mechanical monitoring networks, the Bently Nevada 330101-00-10-10-02-CN (330101 Proximity Probe) provides direct electrical translation of shaft displacement for integration with machine protection platforms.
| Suffix | Description |
|---|---|
| 330101 | Base Model: 3300 XL 8 mm Proximity Probe |
| 00 | Unthreaded Length: 0.0 in |
| 10 | Overall Case Length: 1.0 in |
| 10 | Total Length: 1.0 m (3.3 ft) |
| 02 | Connector: Miniature coaxial ClickLoc connector, standard cable |
| CN | Agency Approval: Country specific (CN) |
| Parameter | Specification |
|---|---|
| Model | 330101-00-10-10-02-CN |
| Brand | Bently Nevada |
| Origin | USA |
| Weight | 2 kg (Shipping weight) |
| Dimensions | 1.0 in case length, 1.0 m cable |
| Operating Temp | -51 deg C to +177 deg C |
| Power Consumption | N/A (Passive transducer) |
| Mounting Thread | 3/8-24 UNF |
The 330101 probe utilizes eddy-current sensing to generate a displacement signal proportional to the gap between the probe tip and the metallic target. Accuracy in rotor dynamics monitoring requires the system to adhere to a calibrated eddy-current probe scaling of 7.87 V/mm. During the mechanical commissioning phase, technicians must conduct gap voltage validation to ensure the transducer operates at a target of -10 VDC when the machine is at steady-state. Proper alignment is mandatory to maintain signal linearity; operation outside the intended gap range results in waveform distortion and incorrect vibration data. To ensure signal integrity, cross-talk suppression must be maintained by ensuring the probe cable is shielded and isolated from high-voltage AC paths.
Q: Can the CN agency approval option be interchanged with other region-specific approvals?
A: No, the CN approval option incorporates specific design and certification requirements for the designated region. Mixing approval types may result in non-compliance with local safety regulations and installation standards.
Q: Is the 1.0 m cable length field-modifiable?
A: No. The system calibration is tied to the total cable length, which includes the probe and extension cable assembly. Modifying the cable length alters the impedance of the signal loop, which prevents proper function with the 3300 XL monitoring system.
تعطل خط إنتاجنا بسبب عطل في شاشة بنتلي نيفادا. وجدناها متوفرة لدينا في المخزون، وقاموا بشحنها إلينا عبر DHL على الفور. عاد خط الإنتاج للعمل في غضون 48 ساعة - لقد أنقذت هذه الشاشة مصنعنا حقًا.
يُعدّ العثور على وحدات أصلية جديدة تمامًا أمرًا بالغ الأهمية لسلامتنا. يُقدّم هذا الفريق مكونات جديدة من المصنع مع شهادات اعتماد كاملة. والتزامهم ببيع المنتجات الجديدة فقط يجعلهم شريكنا الأكثر ثقة.
نستورد قطع غيار هانيويل وشنايدر من هنا منذ عامين. تصل كل شحنة مغلفة بإحكام مع الحفاظ على أختام المصنع الأصلية. نتميز بالتواصل الواضح وأفضل أوقات التسليم في هذا المجال.