أصلي 100%. أكثر من 100,000 قطعة متوفرة. جاهزة للشحن.

  • ar

The Bently Nevada 330703-000-070-10-02-00, also cataloged as the 330704 Proximity Probe, operates as a dedicated hardware component for physical displacement measurement within 3300 XL transducer networks.

Suffix Breakdown & Model Matrix

The part number 330704-000-050-10-02-CN designates specific physical properties based on the Bently Nevada ordering matrix:

  • 330704: Base designator for 3300 XL 11 mm Proximity Probe (with 3/8-24 UNF thread).
  • 000: Unthreaded length option designating 0 mm (no unthreaded section).
  • 050: Overall case length option designating 50 mm.
  • 10: Total length option specifying 1.0 meter (3.3 feet).
  • 02: Connector and cable-type option specifying miniature coaxial ClickLoc connector, standard cable.
  • CN: Agency approval option specifying country-specific approvals for China.

Hardware Specifications

Parameter Specification
Model 330704-000-050-10-02-CN
Brand Bently Nevada
Origin USA
Probe Tip Diameter 11.0 mm
Thread Type 3/8-24 UNF thread
Unthreaded Length 0 mm
Overall Case Length 50 mm
Total Probe Length 1.0 meter (3.3 feet)
Connector Type Miniature coaxial ClickLoc
Operating Temp -51 to +177 deg C
Power Consumption Passive transducer sensor (0 W)
Dimensions 11.0 mm tip, 50 mm case length, 1.0 m cable
Weight 3.0 kg (including shipping packaging)

Eddy-Current Probe Scaling & Gap Voltage Validation

This 11 mm proximity probe relies on eddy-current physics to generate a high-frequency electromagnetic field that measures the distance between the probe tip and a conductive target. To maintain standard eddy-current probe scaling of 3.94 V/mm (100 mV/mil), the probe must be connected via a matched 11 mm extension cable to a calibrated 3300 XL 11 mm Proximitor. Accurate mechanical adjustment during commissioning is necessary to achieve proper gap voltage validation, aiming for a target value of -10 VDC at the physical center of the linear calibration range. Correct physical gapping ensures optimal tracking of rotor dynamics and prevents measurement distortion caused by signal cross-talk suppression between adjacent sensor installations.

Frequently Asked Questions

Q: Can this 330704 probe be connected directly to an 8 mm 3300 XL Proximitor?

A: No. The 11 mm probe tip has distinct electrical impedance properties and a wider sensing field than an 8 mm probe. Interfacing this probe with an 8 mm Proximitor will cause severe impedance mismatching, leading to calibration failure and invalid displacement readings.

Q: What is the purpose of the CN suffix in the product part number?

A: The CN suffix denotes country-specific agency approvals for China. This ensures that the probe meets local regulatory requirements for explosion-proof and intrinsic safety standards in industrial installations.

Field Installation Guidelines

  • Mounting and Torque: Thread the probe into the mounting bracket or sleeve. Do not exceed a tightening torque of 22.6 N-m (200 in-lb) for the UNF threads to prevent damaging the internal components.
  • Adjusting the Gap Voltage: Slowly rotate the probe toward the shaft target while monitoring the Proximitor sensor output voltage. Secure the probe locknut when the voltage matches the target offset of -10.0 VDC.
  • Connector Insulation: Keep the coaxial ClickLoc terminal dry and clean during connection. Ensure the integrated connector protector covers the interface completely to isolate the shield from the machine ground casing.

ماذا يقول عملاؤنا عنا؟

Translation missing: ar.general.search.loading