The Yokogawa AEA4D-06, also cataloged as the AEA4D Terminal Board for Analog, operates as a dedicated hardware component for 16-channel single or dual-redundant field signal termination within CENTUM VP and CS 3000 control systems.
The alphanumeric suffix codes define the protection levels, build variants, and environmental options for this terminal assembly:
| Parameter | Specification |
|---|---|
| Model | AEA4D-06 |
| Brand | Yokogawa |
| Origin | Japan |
| Weight | 1.5 kg |
| Dimensions | Standard 19-inch rack-mountable footprint |
| Operating Temp | 0 to 55 deg C |
| Power Consumption | Negligible (Passive termination board) |
| Channel Capacity | 16 channels, dual-redundant support (32 total terminal points) |
| Terminal Screw Type | M4 screw terminals |
| Interface Cable | KS1 dedicated multi-conductor cable |
| Insulation Resistance | >= 100 MΩ at 500 VDC |
| Withstanding Voltage | 500 VAC for 1 minute |
| Compatible Modules | AAI135, AAI835, AAP135, AAI141, AAV141, AAV142, AAV144, AAB841, AAI841, AAV542, AAV544, AAI143, AAI543 |
This hardware supports 4-20 mA HART loop protocol passes and diverse analog voltage vectors by operating as an unpowered, transparent physical interface layer between field transmitters and FIO modules. The integrated ISA Standard G3 conformal layer prevents atmospheric degradation from corrosive elements, ensuring long-term contact integrity across all 32 M4 screw points. Circuit traces route signals through dedicated redundant termination paths, allowing secondary FIO modules to continuously poll input variables without interrupting loop current stability. A dedicated ground bus establishes low-impedance pathways for drain wires, enforcing cross-talk suppression and maintaining channel isolation metrics under extreme common-mode voltage fluctuations.
Q: Can this terminal board remain active during the replacement of a faulty I/O module?
A: Yes. Because the AEA4D-06 is a completely passive termination board, the connected FIO modules can be hot-swapped without disconnecting the field wiring from the M4 terminals or disrupting the redundant signal bus.
Q: What are the primary installation limitations dictated by the suffix code 6 variant?
A: The suffix code 6 explicitly states this board lacks explosion protection. It cannot be installed within hazardous areas (Class I, Div 1/2 or ATEX Zones) without an approved external intrinsic safety barrier or explosion-proof enclosure.