أصلي 100%. أكثر من 100,000 قطعة متوفرة. جاهزة للشحن.

  • ar

The Bently Nevada 330101-00-08-05-02-00, also cataloged as the 330101 Proximity Probe, operates as a dedicated hardware component for sensing shaft displacement and vibration within machine protection systems.

Suffix Breakdown & Model Matrix

Suffix Description
330101 Base Model: 3300 XL 8 mm Probe, 3/8-24 UNF thread, no armor
00 Unthreaded Length: 0.0 in
08 Overall Case Length: 0.8 in
05 Total Length: 0.5 m (1.6 ft)
02 Connector: Miniature coaxial ClickLoc connector, standard cable
00 Agency Approval: Not required

Hardware Specifications

Parameter Specification
Model 330101-00-08-05-02-00
Brand Bently Nevada
Origin USA
Dimensions 0.8 in case length, 0.5 m cable
Operating Temp -51 deg C to +177 deg C
Power Consumption N/A (Passive transducer)
Probe Diameter 8 mm
Mounting Thread 3/8-24 UNF

Eddy-Current Probe Scaling and Rotor Dynamics

The 330101 probe utilizes eddy-current technology to measure the gap between the probe tip and the metallic target surface. Correct rotor dynamics analysis depends on precise adherence to the factory-calibrated eddy-current probe scaling (typically 7.87 V/mm or 200 mV/mil). During installation, the probe must be adjusted to achieve a gap voltage validation target of -10 VDC when the machine is in a nominal operating state. This ensures the transducer is centered within its linear operating range. Cross-talk suppression is maintained via the coaxial cable design; however, the shield must be correctly terminated at the monitor interface to prevent signal interference from external electromagnetic fields.

Frequently Asked Questions

Q: Can this probe be used in high-pressure environments?

A: The probe assembly is rated for pressure compatibility up to 100 psi (689 kPa) when installed with appropriate thread sealing. Ensure that the sealing method does not introduce contamination into the machine cavity.

Q: Is the ClickLoc connector compatible with non-3300 XL extension cables?

A: The ClickLoc connector is specific to the 3300 XL series. Mating this probe with older style or non-compatible cables will cause impedance mismatches, leading to significant signal degradation and inaccurate vibration readings.

Field Installation Guidelines

  1. Ensure the mounting threads (3/8-24 UNF) are clean and free of debris. Use a non-conductive thread sealant if required by the machine installation manual.
  2. Verify the probe gap using a precision feeler gauge or the monitoring system's DC voltage output; target the manufacturer's recommended gap voltage to ensure the probe remains in the linear measurement zone.
  3. Hand-tighten the probe until contact with the target is made, then back off according to the specified gap distance; torque the lock nut securely to prevent movement during machine operation.
  4. Route the 0.5 m miniature coaxial cable along the machine case using approved cable clips to prevent vibration-induced fatigue and potential cable breakage.