Configured for precision vibration sensing in mechanical monitoring networks, the Bently Nevada 330101-00-12-05-02-05 (330101 Proximity Probe) provides direct electrical translation of shaft displacement for integration with machine protection platforms.
| Suffix | Description |
|---|---|
| 330101 | Base Model: 3300 XL 8 mm Probe, 3/8-24 UNF thread, no armor |
| 00 | Unthreaded Length: 0.0 in |
| 12 | Overall Case Length: 1.2 in |
| 05 | Total Length: 0.5 m (1.6 ft) |
| 02 | Connector: Miniature coaxial ClickLoc connector, standard cable |
| 05 | Agency Approval: CSA, ATEX, IECEx |
| Parameter | Specification |
|---|---|
| Model | 330101-00-12-05-02-05 |
| Brand | Bently Nevada |
| Origin | USA |
| Dimensions | 1.2 in case length, 0.5 m cable |
| Operating Temp | -51 deg C to +177 deg C |
| Power Consumption | N/A (Passive transducer) |
| Probe Diameter | 8 mm |
| Mounting Thread | 3/8-24 UNF |
The 330101 probe utilizes eddy-current technology to measure the gap between the probe tip and the metallic target surface. Correct rotor dynamics analysis depends on precise adherence to the factory-calibrated eddy-current probe scaling (typically 7.87 V/mm). During installation, the probe must be adjusted to achieve a gap voltage validation target of -10 VDC when the machine is in a nominal operating state. This ensures the transducer is centered within its linear operating range. Cross-talk suppression is maintained via the coaxial cable design; however, the shield must be correctly terminated at the monitor interface to prevent signal interference from external electromagnetic fields.
Q: Can this probe be used in hazardous environments?
A: Yes, the 05 suffix indicates that this model includes CSA, ATEX, and IECEx approvals. Always verify the specific zone classification on site documentation and ensure proper barrier or isolator usage according to local safety regulations.
Q: Is the ClickLoc connector compatible with non-3300 XL extension cables?
A: No. The ClickLoc connector is specific to the 3300 XL series. Mating this probe with non-compatible cables will cause impedance mismatches, leading to significant signal degradation and inaccurate vibration readings.
تعطل خط إنتاجنا بسبب عطل في شاشة بنتلي نيفادا. وجدناها متوفرة لدينا في المخزون، وقاموا بشحنها إلينا عبر DHL على الفور. عاد خط الإنتاج للعمل في غضون 48 ساعة - لقد أنقذت هذه الشاشة مصنعنا حقًا.
يُعدّ العثور على وحدات أصلية جديدة تمامًا أمرًا بالغ الأهمية لسلامتنا. يُقدّم هذا الفريق مكونات جديدة من المصنع مع شهادات اعتماد كاملة. والتزامهم ببيع المنتجات الجديدة فقط يجعلهم شريكنا الأكثر ثقة.
نستورد قطع غيار هانيويل وشنايدر من هنا منذ عامين. تصل كل شحنة مغلفة بإحكام مع الحفاظ على أختام المصنع الأصلية. نتميز بالتواصل الواضح وأفضل أوقات التسليم في هذا المجال.