Configured for non-contacting vibration and displacement measurement in machinery monitoring systems, the Bently Nevada 330104-00-14-05-02-00 (330104 Proximity Probe) provides direct physical/electrical execution. The component translates the physical gap between the probe tip and the target rotor into a proportional voltage signal when paired with a matching proximitor sensor.
| Parameter | Specification |
|---|---|
| Model | 330104-00-14-05-02-00 |
| Brand | Bently Nevada |
| Origin | U.S.A. |
| Weight | 0.323 kg |
| Dimensions | M10 x 1 thread, 140 mm overall case length, 0.5 m total length |
| Operating Temp | -51 deg C to +177 deg C |
| Power Consumption | Passive component (driven by proximitor sensor) |
| Thread Configuration | M10 x 1 thread with stainless steel armor |
| Unthreaded Length | 0 mm |
| Overall Case Length | 140 mm |
| Total Length Option | 0.5 meter (1.6 feet) |
| Connector Type | Miniature coaxial ClickLoc connector, standard cable |
| Agency Approval | Not required |
This eddy-current probe relies on definitive scaling parameters to maintain loop accuracy. During field commissioning, cross-talk suppression must be enforced by maintaining a minimum physical clearance between adjacent probe tips to prevent radio frequency interference from corrupting the dynamic signals. Field technicians must perform gap voltage validation to verify that the physical position corresponds to the linear center of the calibration curve. The probe output drives the transducer loop to target an initial bias voltage of -10 VDC, ensuring optimal linear range capture for structural tracking and rotor dynamics analysis under fluctuating thermal profiles.
Q: How should the ClickLoc connector be handled to prevent signal loss?
A: The ClickLoc coaxial connector requires a dry, contamination-free connection. Do not use tools to over-tighten the connection; finger-tighten past the initial click detent. The connection must be insulated from machine ground using silicone connector protectors or self-fusing tape to eliminate ground loop interference.
Q: What are the consequences of mismatching the 0.5-meter probe with non-compliant system cabling?
A: The Bently Nevada 3300 XL 8 mm system requires a total electrical length of either 5.0 meters or 9.0 meters between the probe tip and the proximitor sensor. Because this probe has a 0.5-meter integral cable, it must be paired with a 4.5-meter or 8.5-meter extension cable. Mismatching the total physical length alters the system inductance and capacitance, causing incorrect scale factor calibration.
تعطل خط إنتاجنا بسبب عطل في شاشة بنتلي نيفادا. وجدناها متوفرة لدينا في المخزون، وقاموا بشحنها إلينا عبر DHL على الفور. عاد خط الإنتاج للعمل في غضون 48 ساعة - لقد أنقذت هذه الشاشة مصنعنا حقًا.
يُعدّ العثور على وحدات أصلية جديدة تمامًا أمرًا بالغ الأهمية لسلامتنا. يُقدّم هذا الفريق مكونات جديدة من المصنع مع شهادات اعتماد كاملة. والتزامهم ببيع المنتجات الجديدة فقط يجعلهم شريكنا الأكثر ثقة.
نستورد قطع غيار هانيويل وشنايدر من هنا منذ عامين. تصل كل شحنة مغلفة بإحكام مع الحفاظ على أختام المصنع الأصلية. نتميز بالتواصل الواضح وأفضل أوقات التسليم في هذا المجال.