Configured for 120 VAC discrete load switching in Series 90-70 platforms, the GE IC697MDL350 (IC697MDL350 Discrete Output Module) provides direct physical/electrical execution.
| Parameter | Specification |
|---|---|
| Model | IC697MDL350 |
| Brand | GE Fanuc Emerson |
| Origin | USA / Global Manufacturing |
| Weight | 0.34 kg (0.75 lbs) |
| Dimensions | Single-Slot Series 90-70 Module Form Factor |
| Operating Temp | 0 to 60 deg C |
| Power Consumption | 0.5 A required current (via backplane bus) |
| Series | Series 90-70 |
| Product Type | Discrete Output Modules |
| Outputs | 32 points (4 isolated groups of 8 points each) |
| Rated Voltage | 120 VAC |
| Operating Frequency | 47 to 63 Hz |
| Continuous Current per Point | 0.5 A |
| Maximum Current per Group | 2 A |
| Group Fuse Protection | 5 A fuse per 8-point group |
| Inrush Capacity | 20 times rated current |
| Status Indicators | Per-point output LEDs, fuse status LED |
The IC697MDL350 updates output status bytes over the Series 90-70 backplane bus based on execution commands from the central processor. Deterministic backplane bus communication velocity guarantees prompt response across all 32 channel outputs during controller scan cycles.
Soft configuration via programming software eliminates physical jumpers and DIP switches. Firmware flash compatibility across Series 90-70 host CPUs enables flexible I/O density scaling. The 4-group isolation allows individual 8-point banks to operate from distinct AC line phases, while 20x inrush current capacity supports inductive field loads such as contactors, solenoids, and motor starters.
Q: How is circuit protection configured across the output channels of the IC697MDL350?
A: The 32 output points are organized into 4 isolated groups of 8 points, with each individual group protected by a 5 A fuse monitored by a dedicated status LED.
Q: Can the IC697MDL350 operate output groups from different AC power phases?
A: Yes, each isolated 8-point output group can be connected to a different AC supply phase operating within 47 to 63 Hz.
Q: Does module configuration require physical hardware jumper or DIP switch adjustments?
A: No, I/O referencing and operational parameters are configured strictly through system programming software over the CPU interface.