The GE IC693PWR321, also cataloged as the IC693PWR321 Standard Power Supply, operates as a dedicated hardware component for converting line input power into regulated internal operating voltages within Series 90-30 PLC platforms.
| Parameter | Specification |
|---|---|
| Model | IC693PWR321 |
| Brand | GE Fanuc / Emerson |
| Origin | Factory standard |
| Weight | 0.51 kg (1.13 lbs) |
| Dimensions | Single-slot wide (Occupies leftmost dedicated baseplate slot) |
| Operating Temp | 0 to 60 deg C (Standard industrial environment) |
| Power Consumption | Input requirement: 90 VA (AC input) / 50 W (DC input) |
| Nominal Rated Voltage | 120 / 240 VAC or 125 VDC |
| Input Voltage Range, AC | 85 to 264 VAC |
| Input Voltage Range, DC | 100 to 300 VDC |
| Total Output Power Rating | 30 W maximum |
| 5 VDC Output Capacity | 5.0 to 5.2 VDC (5.1 VDC nominal); 15 W maximum |
| 24 VDC Relay Output Capacity | 24 to 28 VDC; 15 W maximum |
| 24 VDC Isolated Output Capacity | 21.5 to 28 VDC; 20 W maximum |
| Inrush Current | 4 A peak, 250 ms maximum |
| Holdup Time | 20 ms minimum |
| Overvoltage Protection | 6.4 to 7.0 VDC (on 5 VDC rail) |
| Overcurrent Protection | 4.0 A maximum short-circuit current limit |
| Communication Interface | 1 x 9-pin sub-D connector (RS-485 serial protocol) |
| Internal Fuse Reference | GE 44A724627-109 / Bussmann GDC-2 / Littelfuse 239-002 |
The module installs exclusively into the leftmost slot of the Series 90-30 baseplate to directly drive the internal parallel power rails. It splits its 30 W total output across three specialized internal circuits to allow for robust I/O density scaling without inducing voltage sag. The 5 VDC rail supports local CPU logic processing, while the 24 VDC relay power rail energizes discrete output coil modules. An independent 24 VDC isolated rail supplies external power to select analog or communication modules, maintaining power separation across the deterministic backplane network.
Q: What is the electrical behavior of the power supply during a direct short circuit on the field side?
A: The module contains an internal power supply limiting feature that initiates overcurrent protection when current demands reach a maximum of 4.0 A. This automatically limits output power to safeguard the internal backplane components immediately upon detection of a direct short.
Q: Can this power supply module be hot-swapped while the primary line voltage is active?
A: No. The physical design and electrical architecture of the Series 90-30 baseplate require total isolation of input line power and external loops prior to extracting or inserting the power supply unit.
Q: What is the significance of the holdup time specification for this module?
A: The minimum holdup time is 20 ms. This guarantees that the power supply will maintain regulated DC output voltages during brief line power interruptions up to 20 ms, preventing immediate CPU halts or data drops during transient power fluctuations.
تعطل خط إنتاجنا بسبب عطل في شاشة بنتلي نيفادا. وجدناها متوفرة لدينا في المخزون، وقاموا بشحنها إلينا عبر DHL على الفور. عاد خط الإنتاج للعمل في غضون 48 ساعة - لقد أنقذت هذه الشاشة مصنعنا حقًا.
يُعدّ العثور على وحدات أصلية جديدة تمامًا أمرًا بالغ الأهمية لسلامتنا. يُقدّم هذا الفريق مكونات جديدة من المصنع مع شهادات اعتماد كاملة. والتزامهم ببيع المنتجات الجديدة فقط يجعلهم شريكنا الأكثر ثقة.
نستورد قطع غيار هانيويل وشنايدر من هنا منذ عامين. تصل كل شحنة مغلفة بإحكام مع الحفاظ على أختام المصنع الأصلية. نتميز بالتواصل الواضح وأفضل أوقات التسليم في هذا المجال.