The GE Fanuc IC695ALG626, also cataloged as the IC695ALG626 Non-isolated Analog Input Module, operates as a dedicated hardware component for multi-channel voltage/current signal processing and HART transducer communication within PACSystems RX3i platforms.
| Parameter | Specification |
|---|---|
| Model | IC695ALG626 |
| Brand | GE Fanuc Emerson |
| Origin | USA |
| Weight | 0.63 lbs (0.28 kg) |
| Dimensions | Single-slot PACSystems RX3i module width |
| Operating Temp | 0 to 60 deg C (32 to 140 deg F) |
| Power Consumption | 600 mA at 3.3 VDC; 450 mA at 5 VDC |
| Input Channel Count | 16 single-ended or 8 differential channels |
| Current Signal Ranges | 0 to 20 mA, 4 to 20 mA, +/-20 mA |
| Voltage Signal Ranges | +/-10 VDC, 0 to 10 VDC, +/-5 VDC, 0 to 5 VDC, 1 to 5 VDC, +/-50 mV, +/-150 mV |
| Digital Resolution | 24-bit ADC converted to floating point IEEE 32-bit or 16-bit integer |
| Current Input Resistance | 249 ohms +/-1% |
| Voltage Input Impedance | >100 kohms |
| Configurable Input Filters | 8 Hz, 12 Hz, 16 Hz, 40 Hz, 200 Hz, 500 Hz |
| HART Protocol Support | HART Version 5.0 with 4 internal HART modems |
| Maximum Input Limits | Continuous overvoltage: +/-60 VDC; Continuous overcurrent: +/-28 mA |
| Operating Humidity | 5 to 95%, non-condensing |
The IC695ALG626 enhances backplane bus communication velocity across the PACSystems RX3i universal backplane by executing 24-bit analog-to-digital conversions directly into 32-bit floating point or integer memory structures. Configured for I/O density scaling, the single-slot footprint provides up to 16 single-ended or 8 differential input channels alongside 4 embedded HART modems for digital pass-through data acquisition. Module parameters feature full software configuration without jumpers, while onboard firmware flash compatibility supports startup autocalibration, open circuit fault detection, and real-time high/low limit alarms.
Q: What power rails are drawn from the RX3i backplane by the IC695ALG626?
A: The module draws 600 mA from the internal 3.3 VDC bus rail and 450 mA from the internal 5 VDC bus rail.
Q: Does the IC695ALG626 support hot-swapping on the PACSystems RX3i backplane?
A: Yes, the hardware supports insertion and removal under power (hot-swapping) when installed in a PACSystems RX3i universal backplane.
Q: What specific input range is required when utilizing HART communication?
A: Channels utilizing HART Version 5.0 digital communications must be software-configured for the 4 to 20 mA current range.