The GE IC695PBM300, also cataloged as the IC695PBM300 PROFIBUS Master Module, operates as a dedicated hardware component for deterministic fieldbus communication execution within PACSystems RX3i PCI backplane architectures.
| Parameter | Specification |
|---|---|
| Model | IC695PBM300 |
| Brand | GE Fanuc / Emerson Automation |
| Origin | USA |
| Weight | 0.14 kg (0.31 lbs) |
| Dimensions | Single-slot PACSystems RX3i module format |
| Operating Temp | 0 to 60 deg C |
| Storage Temp | -40 to 85 deg C |
| Power Consumption | 1.45 W maximum (440 mA @ 3.3 VDC) |
| Backplane Interface | RX3i Universal Backplane (PCI connection) |
| Communication Interface | 1 PROFIBUS Master Port |
| Communication Protocols | PROFIBUS DP, DP-V1 Read/Write/Alarm |
| Supported Slave Capacity | Up to 125 PROFIBUS DP slaves |
| Network Data Exchange Capacity | 3584 Bytes maximum input data, 3584 Bytes maximum output data |
| Per-Slave Exchange Limit | 244 Bytes input data, 244 Bytes output data |
| Supported Baud Rates | 9.6 kBit/s, 19.2 kBit/s, 93.75 kBit/s, 187.5 kBit/s, 500 kBit/s, 1.5 MBit/s, 3 MBit/s, 6 MBit/s, 12 MBit/s |
| Auxiliary Control Modes | Sync mode, Freeze mode |
| System Firmware Requirements | RX3i Controller Firmware v2.90 or later |
| Diagnostics & Status Data | Slave Status Bit Array Table, Network Diagnostic Counters, DP Master Diagnostic Counters, Slave Diagnostic Address |
| LED Indicators | PROFIBUS OK LED, Network LED, MOD Status LED |
The module manages high-speed fieldbus data transfers over Profinet / EtherNet/IP deterministic networks and PCI backplane bus interfaces. Operating across configurable baud rates up to 12 MBit/s, the hardware maintains backplane bus communication velocity while maintaining firmware flash compatibility via indirect updates using the host controller and WinLoader utility.
Q: What are the backplane power supply requirements for the IC695PBM300?
A: The module draws 440 mA exclusively from the 3.3 VDC backplane power rail on the RX3i PCI universal backplane.
Q: How is firmware updated on the IC695PBM300 module?
A: Firmware flash upgrades are performed indirectly through the host RX3i controller utilizing the WinLoader software utility.
Q: What system software and CPU firmware versions are required to run the IC695PBM300?
A: The host RX3i controller must run firmware version 2.90 or higher to support communications with the module.
تعطل خط إنتاجنا بسبب عطل في شاشة بنتلي نيفادا. وجدناها متوفرة لدينا في المخزون، وقاموا بشحنها إلينا عبر DHL على الفور. عاد خط الإنتاج للعمل في غضون 48 ساعة - لقد أنقذت هذه الشاشة مصنعنا حقًا.
يُعدّ العثور على وحدات أصلية جديدة تمامًا أمرًا بالغ الأهمية لسلامتنا. يُقدّم هذا الفريق مكونات جديدة من المصنع مع شهادات اعتماد كاملة. والتزامهم ببيع المنتجات الجديدة فقط يجعلهم شريكنا الأكثر ثقة.
نستورد قطع غيار هانيويل وشنايدر من هنا منذ عامين. تصل كل شحنة مغلفة بإحكام مع الحفاظ على أختام المصنع الأصلية. نتميز بالتواصل الواضح وأفضل أوقات التسليم في هذا المجال.