The Yokogawa KS1-03*B, also cataloged as the KS1 Signal Cable, operates as a dedicated hardware component for multi-bus data transmission between I/O modules and terminal boards within Yokogawa CENTUM VP and ProSafe-RS control systems. Built with multi-strand high-grade copper conductors and dual-layer braided shielding, this 3 m cable assembly maintains physical transmission paths across V net (10BASE-5), ER bus (10BASE-2), ESB bus, and RIO bus physical network layers. The rugged assembly suppresses ambient electromagnetic interference (EMI) to deliver non-attenuated signal execution between local control nodes and field terminal interfaces.
| Model Code | Cable Length | Style Code | Option Code | Functional Description |
|---|---|---|---|---|
| KS1 | Base Model | -- | -- | System I/O Signal Cable Assembly |
| -03 | 3 meters | -- | -- | Fixed cable length specification |
| *B | -- | Style B | -- | Specific shielding architecture and connector layout |
| /NL | -- | -- | /NL | Optional CSA non-incendive rating for hazardous locations |
| Parameter | Specification |
|---|---|
| Model | KS1-03*B |
| Brand | Yokogawa |
| Origin | USA |
| Weight | 0.57 kg net (0.9 kg shipping) |
| Dimensions | 25.4 cm x 5.1 cm x 38.1 cm (packaged) |
| Operating Temp | -20 deg C to +70 deg C |
| Power Consumption | Passive physical media component (0 W) |
| Cable Length | 3 meters |
| Shielding Topology | Braided shield + foil wrap (dual-layer EMI protection) |
| Conductor Material | Multi-strand high-grade copper |
| Cable Construction | Coaxial (V net / ER bus), Twisted pair (ESB / RIO bus) |
| Connector Options | System-dependent 40-pin, N-type, BNC, or M4 screw lugs |
| Minimum Bending Radius | 50 mm to 100 mm |
The KS1-03*B signal cable accommodates 4-20 mA HART loop protocol carrier frequencies by preserving signal wave integrity over its low-loss polyethylene/PVC dielectric paths. When routing analog telemetry between field terminal blocks and DCS input cards, the multi-strand twisted-pair geometry restricts cross-channel capacitive coupling, preventing channel-to-channel isolation degradation across adjacent process loops. The low-impedance braided outer shield drains induced high-frequency electrical noise to ground, ensuring precise cold junction compensation (CJC) mV reference readings from field thermocouples connected to terminal boards.
Q: How does the dual-layer shielding affect grounding procedures during installation?
A: The combined braided shield and foil wrap isolate signal lines from high-frequency electromagnetic noise. To prevent ground potential loop currents across the shield, terminate the drain wire or braided shield to functional earth at one designated cabinet end only.
Q: Can this cable be deployed in hazardous locations requiring explosion protection?
A: When ordered with the /NL option code, the assembly complies with CSA non-incendive instrumentation standards for installation in designated Division 2 hazardous area environments without compromising signal execution.
Q: What is the mechanical limitation regarding cable routing inside crowded control cabinets?
A: Field technicians must maintain a minimum bending radius of 50 mm to 100 mm depending on the specific bus cable type (coaxial vs. twisted-pair). Exceeding this bend limit risks damaging the inner dielectric insulation and compromising EMI shield coverage.
تعطل خط إنتاجنا بسبب عطل في شاشة بنتلي نيفادا. وجدناها متوفرة لدينا في المخزون، وقاموا بشحنها إلينا عبر DHL على الفور. عاد خط الإنتاج للعمل في غضون 48 ساعة - لقد أنقذت هذه الشاشة مصنعنا حقًا.
يُعدّ العثور على وحدات أصلية جديدة تمامًا أمرًا بالغ الأهمية لسلامتنا. يُقدّم هذا الفريق مكونات جديدة من المصنع مع شهادات اعتماد كاملة. والتزامهم ببيع المنتجات الجديدة فقط يجعلهم شريكنا الأكثر ثقة.
نستورد قطع غيار هانيويل وشنايدر من هنا منذ عامين. تصل كل شحنة مغلفة بإحكام مع الحفاظ على أختام المصنع الأصلية. نتميز بالتواصل الواضح وأفضل أوقات التسليم في هذا المجال.