Configured for multi-signal data acquisition in SL1000 systems, the YOKOGAWA S9361DH-00 (S9361DH-00 Terminal Board Module) provides direct physical/electrical execution of voltage, temperature, and logic signal interfacing.
| Parameter | Specification |
| Model | S9361DH-00 |
| Brand | YOKOGAWA |
| Origin | Japan |
| Weight | 0.24 kg |
| Dimensions | 17.8 cm x 4.6 cm x 24.9 cm |
| Operating Temp | -20 deg C to +70 deg C |
| Power Consumption | 24 VDC +/- 10% |
| Signal Types | Voltage (mV/V), Thermocouple (TC), RTD, Digital I/O |
| Channel Count | 20 channels |
| Accuracy | +/- 0.1% full scale |
| Sampling Rate | Up to 1000 samples/sec |
The YOKOGAWA S9361DH-00 incorporates advanced channel-to-channel and channel-to-ground isolation to mitigate electromagnetic interference and potential ground loops within high-precision measurement environments. The module features integrated cold junction compensation (CJC) circuitry, which autonomously adjusts for thermal gradients during thermocouple signal processing. By providing dedicated sensor excitation voltages, the board ensures stable resistance temperature detector (RTD) readings while maintaining 16-bit analog-to-digital resolution across all input channels.
Q: What are the installation constraints for this terminal board?
A: The board is designed for panel or rack mounting. Ensure adequate clearance to maintain specified operating temperatures (-20 deg C to +70 deg C) and verify that all incoming field wiring is properly shielded to preserve isolation integrity.
Q: How does the module handle thermocouple measurements?
A: The module utilizes an onboard cold junction compensation (CJC) sensor to calibrate terminal temperatures in real-time, which eliminates the requirement for external reference junctions and ensures measurement accuracy of +/- 0.1% full scale.
Mounting: Secure the board using standard panel or rack-mount fasteners. Confirm that the mechanical chassis is grounded to the system common to facilitate high-frequency noise suppression.
Wiring: Terminate field wiring using the designated screw terminals. For thermocouple or low-voltage signal paths, ensure that cable shields are grounded at the source or the module entry point as per standard industrial instrumentation practices.
Verification: Before applying the 24 VDC supply, verify that all sensor connections (RTD, TC, and voltage) are seated correctly to prevent open-circuit inputs.
Maintenance: Periodically inspect terminal connections for oxidation or mechanical fatigue resulting from vibration, particularly in automotive testing or heavy industrial environments.
تعطل خط إنتاجنا بسبب عطل في شاشة بنتلي نيفادا. وجدناها متوفرة لدينا في المخزون، وقاموا بشحنها إلينا عبر DHL على الفور. عاد خط الإنتاج للعمل في غضون 48 ساعة - لقد أنقذت هذه الشاشة مصنعنا حقًا.
يُعدّ العثور على وحدات أصلية جديدة تمامًا أمرًا بالغ الأهمية لسلامتنا. يُقدّم هذا الفريق مكونات جديدة من المصنع مع شهادات اعتماد كاملة. والتزامهم ببيع المنتجات الجديدة فقط يجعلهم شريكنا الأكثر ثقة.
نستورد قطع غيار هانيويل وشنايدر من هنا منذ عامين. تصل كل شحنة مغلفة بإحكام مع الحفاظ على أختام المصنع الأصلية. نتميز بالتواصل الواضح وأفضل أوقات التسليم في هذا المجال.