The Yokogawa KS10-25*A, also cataloged as the KS10 Signal Cable (50-50 pins), operates as a dedicated hardware component for 32-channel I/O signal interconnectivity within Yokogawa CENTUM VP and ProSafe-RS control systems. Configured with a 50-pin to 50-pin interface structure across a 25 m length, the cable transfers discrete and analog field instrumentation signals directly between I/O cards, terminal boards, and system node units. The assembly utilizes shielded twisted-pair conductors to preserve signal parameters across V net, ER bus, ESB bus, and RIO bus physical network layers.
| Parameter | Specification |
|---|---|
| Model | KS10-25*A |
| Brand | Yokogawa |
| Origin | Japan / China |
| Weight | 1.5 kg |
| Dimensions | 25 m cable length (50-pin to 50-pin) |
| Operating Temp | -20 to +60 deg C |
| Power Consumption | Passive physical conductor assembly (0 W) |
| Signal Capacity | Up to 32 I/O channels |
| Cable Construction | Shielded twisted-pair, flame-resistant jacket |
| Connector Configuration | Dual 50-pin multi-conductor connectors |
| Minimum Bending Radius | 50 to 100 mm |
| Supported System Buses | V net, ER bus, ESB bus, RIO bus |
The KS10-25*A cable supports high-density multi-channel analog signaling, enabling 4-20 mA HART loop protocol pass-through without signal attenuation or digital frequency distortion. The internal twisted-pair conductor geometry limits inter-pair crosstalk, allowing multi-core routing of sensitive 1-5 V DC and 4-20 mA instrument loops alongside HART digital carrier frequencies. When connected to isolated terminal blocks, the continuous foil shielding preserves individual channel-to-channel isolation barriers and shields cold junction compensation (CJC) reference lines from ambient low-frequency electromagnetic interference.
Q: Does the 25 m cable length induce significant signal voltage drops on 4-20 mA current loops?
A: No. The low-resistance copper conductors are sized to maintain negligible voltage drop over 25 m, allowing standard 2-wire 24 V DC transmitter loops to operate within nominal voltage tolerances.
Q: Can the cable shield be grounded at both terminal ends?
A: System wiring specifications require grounding the overall cable braid shield at a single defined ground terminal bar (typically on the control cabinet frame) to prevent ground loop currents from flowing through the shield braid.
Q: How does the cable jacket react when installed near high-temperature steam lines?
A: The flame-resistant industrial outer jacket withstands continuous ambient operating temperatures up to +60 deg C. For installations exceeding +60 deg C, mechanical heat shielding or alternate conduit routing is required.