Configured for analog signal acquisition in Foxboro I/A Series DCS networks, the Foxboro P0926GQ (P0926GQ Analog Input Modules) provides direct physical/electrical execution. The module processes 16 isolated analog input channels accepting standard 4-20 mA DC transmitter signals across a 12-bit to 16-bit analog-to-digital conversion scale. Operating on a nominal 24 VDC backplane power feed with an 8 W power dissipation profile, the rack-mounted hardware maintains full channel-to-channel and channel-to-system galvanic isolation to suppress common-mode electrical noise across redundant Fieldbus communication paths.
| Parameter | Specification |
|---|---|
| Model | P0926GQ |
| Brand | Foxboro |
| Origin | USA |
| Weight | 0.74 kg (1.63 lbs) |
| Dimensions | 23 cm x 22 cm x 6 cm |
| Operating Temp | 0 deg C to +60 deg C |
| Power Consumption | ~8 W at 24 VDC nominal |
| Product Type | Analog Input Modules |
| Signal Input | 16 channels, 4-20 mA DC range |
| Resolution | 12-bit to 16-bit A/D conversion |
| Galvanic Isolation | Channel-to-channel and channel-to-system isolation |
| System Bus | Foxboro I/A Series redundant Fieldbus |
| Diagnostics | Integrated channel health monitoring, watchdog, and status LEDs |
| Storage Temp | -40 deg C to +85 deg C |
| Operating Humidity | 5% to 95% non-condensing |
The analog input fieldbus module conditions pressure, temperature, flow, and level transmitter telemetry before broadcasting digitized process variables to central control processors. When interfacing field instruments operating over the 4-20 mA HART loop protocol, internal galvanic isolation barriers decouple sensor wiring loops, eliminating ground loops that corrupt signal accuracy. Continuous internal diagnostic routines run in the background to verify A/D conversion linearity, sense wire integrity, and backplane health, illuminating front-panel LEDs to indicate channel faults without interrupting real-time control execution.
Q: How does channel-to-channel galvanic isolation prevent system-wide signal degradation?
A: Optical and transformer barriers isolate each 4-20 mA current loop independently. An electrical short or ground potential shift on one field transmitter remains isolated to that channel, preserving normal operation across the remaining 15 inputs.
Q: Is live insertion and removal supported during active controller operation?
A: Yes, the hot-swappable module incorporates staggered pin connectors on the rear interface, ensuring frame ground and 24 VDC power engage before data communication lines to prevent signal bus interruption during online maintenance.
Nuestra línea de producción se paró debido a un monitor Bently Nevada defectuoso. Lo encontramos en stock aquí y lo enviaron por DHL de inmediato. Volvió a funcionar en 48 horas, lo que realmente salvó nuestra planta.
Encontrar módulos nuevos y originales es fundamental para nuestra seguridad. Este equipo entrega componentes de fábrica con certificación completa. Su compromiso de vender únicamente productos nuevos los convierte en nuestro socio de mayor confianza.
Llevamos dos años abasteciendo aquí piezas de Honeywell y Schneider. Todos nuestros envíos llegan perfectamente embalados, con los precintos originales de fábrica intactos. Ofrecemos una comunicación clara y los mejores plazos de entrega del sector.