The Allen-Bradley 1756-OF8 stands as a cornerstone for precision signal delivery within the ControlLogix ecosystem. This high-density module provides eight individually configurable outputs, allowing engineers to drive actuators, control valves, and variable frequency drives (VFDs) with exceptional accuracy. By supporting both ±10V voltage and 0–20 mA current loops, the 1756-OF8 simplifies inventory and design by handling diverse field device requirements within a single chassis slot.
Condition Statement: We supply this 1756-OF8 in 100% Brand New, Factory Sealed condition, ensuring maximum reliability and the full integrity of its internal R-Ladder DAC architecture.
The 1756-OF8 utilizes a monotonic R-Ladder Digital-to-Analog Converter (DAC) to eliminate missing codes and ensure smooth signal transitions.
| Feature | Details |
| Output Channels | 8 Voltage or Current (individually configurable) |
| Output Ranges | ±10.4V DC, 0–21 mA, 4–20 mA |
| Resolution | 15-bit (320 µV/bit or 650 nA/bit) |
| Settling Time | < 2 ms to 95% of final value (resistive loads) |
| Calibrated Accuracy | Better than 0.05% of range @ 25°C |
| Isolation Voltage | 250V continuous (Channels-to-Backplane) |
| Backplane Current | 150 mA @ 5.1V DC / 210 mA @ 24V DC |
| Drive Capability | >2000 Ω (Voltage); 0–750 Ω (Current) |
| Protection | Short-circuit (≤21 mA) and 24V Overvoltage |
| RTB Options | 1756-TBNH or 1756-TBSH |
The 1756-OF8 addresses critical industrial pain points through high-performance circuitry and robust hardware design:
Eliminate Signal Lag: The module achieves a settling time of less than 2 ms. This fast response enables high-speed PID loops to stabilize quicker, significantly improving the performance of dynamic motion and flow control applications.
Precision Actuation: 15-bit resolution provides the fine-grained control necessary for sensitive dosing pumps and precision positioning valves, minimizing process variability.
Built-in Loop Diagnostics: The 1756-OF8 includes open-circuit detection for current outputs. If a wire breaks or a device fails, the module immediately flags the error to the controller, reducing troubleshooting downtime.
Thermal Efficiency: Despite its high density, the module manages power dissipation effectively (as low as 3.15 W depending on load), preventing heat buildup within the ControlLogix chassis and extending the life of adjacent modules.
Can I mix voltage and current outputs on the same module?
Yes. The 1756-OF8 allows you to configure each of the eight channels independently via Studio 5000 software. You can drive a 4-20 mA valve on Channel 0 and a 0-10V VFD reference on Channel 1 simultaneously.
Does the 1756-OF8 require external power?
While the module draws 210 mA at 24V DC from the ControlLogix backplane, the actual field-side signals are powered through the chassis. Ensure your 1756 power supply has sufficient capacity for the combined current draw of all installed modules.
How often should I calibrate the 1756-OF8?
Rockwell Automation recommends a typical calibration interval of 12 months to maintain the 0.05% accuracy specification, especially in environments with significant temperature fluctuations.
What is the difference between Series A and Series B?
Series A is the original design. While newer series may offer minor component updates or firmware enhancements, the core technical specs like the 2 ms settling time and 15-bit resolution remain compatible for drop-in replacements.
Our production line was down due to a faulty Bently Nevada monitor. We found it in stock here and they shipped it via DHL immediately. Back in operation within 48 hours—truly a lifesaver for our plant.
Finding brand new, original modules is critical for our safety. This team delivers factory-fresh components with full certification. Their commitment to only selling new products makes them our most trusted partner.
We have sourced Honeywell and Schneider parts here for two years. Every shipment arrives well-packaged with original factory seals intact. Clear communication and the best lead times in the industry.