The Allen-Bradley 1769-2WS, also cataloged as the 1769-2WS Dual-Channel Weigh Scale Interface, operates as a dedicated hardware component for strain gauge-based load cell data acquisition within Compact I/O platforms. Configured for direct physical connection to weigh sensors, the device samples physical force signals and transfers calibrated data registers directly to a CompactLogix or MicroLogix 1500 controller across the system backplane.
| Parameter | Specification |
|---|---|
| Model | 1769-2WS |
| Brand | Allen-Bradley |
| Origin | USA |
| Weight | 0.28 kg |
| Dimensions | Standard 1769 Compact I/O module profile |
| Operating Temp | -40 to +70 deg C |
| Power Consumption | 5.1 VDC at 2.0 A maximum backplane current draw |
| Module Type | Dual-Channel Weigh Scale Interface |
| Excitation Voltage | 5 VDC +-1% (Regulated) |
| Load Cell Support | Up to eight 350-ohm sensors (4 per channel) |
| Internal Resolution | 24-bit internal ADC |
| Input Signal Range | -0.5 mV/V to +3.5 mV/V |
| Isolation | 1500 VDC (Channel-to-Channel and Channel-to-Backplane) |
| Sample Rate | 10 to 250 samples per second (User-selectable) |
| Calibration Type | Software-based (Zero, Span, and Tare via PLC logic) |
The weigh module interfaces with the processor via the native backplane bus communication velocity. It utilizes a 24-bit internal Analog-to-Digital Converter (ADC) to transform millivolt-level strain gauge readings into digital values, managing real-time data streaming without requiring external transmitters. This configuration maximizes local I/O density scaling by supporting up to four 350-ohm load cells per channel on two fully independent circuits. The 1500 VDC isolation barrier separates field-side sensor loops from the digital logic bus, preventing high-frequency common-mode noise propagation across deterministic networks.
Q: What is the maximum distance supported between the 1769-2WS module and the connected load cells?
A: The physical distance depends on wire gauge and ambient electrical noise, but standard implementations require 6-wire shielded cable for distances exceeding 15 meters to offset excitation voltage drops through automatic remote sensing.
Q: Can this module operate in an I/O bank located away from the primary controller?
A: Yes. The module is fully compatible with the 1769-AENTR Ethernet adapter, allowing installation in decentralized remote I/O configurations across deterministic EtherNet/IP networks.