The Allen-Bradley 1769-IF16V, also cataloged as the 1769-IF16V Compact I/O Analog Voltage Input Module, operates as a dedicated hardware component for high-density voltage signal acquisition within CompactLogix and MicroLogix 1500 control system platforms.
| Parameter | Specification |
|---|---|
| Model | 1769-IF16V |
| Brand | Allen-Bradley / Rockwell Automation |
| Origin | USA |
| Weight | 0.27 kg |
| Dimensions | 118 x 35 x 87 mm |
| Operating Temp | 0 to 60 deg C |
| Power Consumption | 24 VDC |
| Input Type | 16 single-ended voltage channels |
| Input Signal Range | +/- 10 VDC, 0 to 10 VDC, 0 to 5 VDC, 1 to 5 VDC |
| Resolution | 16-bit (15 bits plus sign) |
| Input Impedance | > 1 Mohm |
| Full Scale Accuracy | +/- 0.1% |
| Isolation Voltage | 750 VDC (Field side to system side) |
| Diagnostics | Module status LEDs |
The 1769-IF16V transfers digitized voltage readings directly across the Compact I/O backplane bus, maintaining deterministic synchronization with the main controller CPU. When integrated into Profinet or EtherNet/IP deterministic networks via 1769-AENTR communication adapters, the module preserves backplane bus communication velocity while maintaining high data throughput across all 16 channels. The 16-bit resolution converter converts analog field levels into engineering units without introducing scan latency. High I/O density scaling doubles channel capacity per slot compared to 8-point modules, while internal firmware flash compatibility ensures uniform deployment across legacy and modern Logix control racks.
Q: Does the 1769-IF16V module accept 4-20 mA current signals directly?
A: No. The internal conversion circuitry measures voltage ranges exclusively (+/- 10 VDC, 0 to 10 VDC, 0 to 5 VDC, and 1 to 5 VDC). Current loop measurement requires the 1769-IF16C current module.
Q: How does the high input impedance affect field transmitter connections?
A: The input impedance rating exceeding 1 Mohm minimizes current draw from field transmitters, preventing signal attenuation and voltage loading errors across long cable lengths.
Q: Is external power required in addition to the 1769 backplane connection?
A: Yes. Although the module communicates over the backplane bus, external 24 VDC power must connect to the terminal block to energize internal analog-to-digital processing loops.