Configured for discrete high-voltage level detection in PLC-5 platforms, the Allen-Bradley 1771-IMD/B (1771-IMD Digital AC/DC Input Module) provides direct physical/electrical execution.
| Parameter | Specification |
|---|---|
| Model | 1771-IMD |
| Brand | Allen-Bradley |
| Origin | USA |
| Weight | 2.31 lbs (1.05 kg) |
| Dimensions | Standard 1771 chassis slot size |
| Operating Temp | 0 to 60 deg C |
| Power Consumption | Backplane current: 250 mA @ 5 VDC |
| Number of Inputs | 16 channels |
| Nominal Voltage | 220 V AC/DC |
| AC Operating Voltage | 184 to 250 V AC |
| DC Operating Voltage | 166 to 230 V DC |
| Max AC Off-State Current | 13.0 mA |
| Max DC Off-State Current | 0.25 mA |
| Typical AC Signal Delay | On: 15 (+/- 8) ms / Off: 172 (+/- 56) ms |
| Typical DC Signal Delay | On: 15 (+/- 8) ms / Off: 172 (+/- 56) ms |
| Wiring Arm Option | 1771-WH / 1771-WA |
| Enclosure Type | Open-style (Rack mountable) |
The 1771-IMD manages discrete signal processing synchronized with the backplane bus communication velocity constraints of the legacy 1771 rack infrastructure. The hardware coordinates wide-area I/O density scaling routines by feeding state registers back to central processors linked across Profinet / EtherNet/IP deterministic networks via communication adapters. Ensuring verified firmware flash compatibility across all adjacent processing blocks is necessary to stabilize input filter updates and guarantee that the 16-channel switching states map into the processor image table without cyclic timing mismatches.
Q: Does the 1771-IMD allow Removal and Insertion Under Power (RIUP)?
A: No. The 1771 I/O chassis backplane structure does not support hot-swapping functionality. The primary power supply feeding the rack must be completely isolated and de-energized prior to inserting or removing this input module to prevent physical degradation of the electrical contacts or logic gates.
Q: How are field wiring connections established for this 16-channel module?
A: Field connections are landed on a dedicated terminal structure using either the 1771-WH or 1771-WA wiring arm. This allows the module to be extracted for maintenance without lifting individual high-voltage AC or DC field loop conductors.