Configured for dynamic shaft vibration and axial position measurement in tight-clearance rotating machinery monitoring loops, the Bently Nevada 330910-00-03-10-02-00 (330910 Proximity Probe) provides direct physical/electrical execution. It generates a localized radio frequency field at the probe tip to detect shaft displacement, transmitting high-frequency voltage proportional signals through an armored coaxial cable to a downstream 3300 NSv Proximitor sensor.
| Option Code | Specification Parameter | Value / Description |
|---|---|---|
| 330910 | Base Model | 3300 NSv Probe, M10 x 1 Thread, with Armor |
| -00 | Unthreaded Length Option | 00 mm |
| -03 | Overall Case Length Option | 30 mm |
| -10 | Total Length Option | 1.0 metre (39 in) |
| -02 | Connector and Cable-Type Option | Miniature coaxial ClickLoc connector, standard cable |
| -00 | Agency Approval Option | Not required |
| Parameter | Specification |
|---|---|
| Model | 330910-00-03-10-02-00 |
| Brand | Bently Nevada |
| Origin | USA |
| Weight | Approx 0.14 kg (Shipping Weight 1.5 kg) |
| Dimensions | M10 x 1 thread, 30 mm case length, 1.0 m cable |
| Operating Temp | -51 deg C to +177 deg C (-60 deg F to +350 deg F) |
| Power Consumption | Passive transducer (driven by external Proximitor driver circuit) |
| Thread Type | Metric M10 x 1 threads |
| Unthreaded Length | 0 mm |
| Overall Case Length | 30 mm |
| Total System Length | 1.0 metre (39 in) |
| Cable Armor | Flexible stainless steel armor outer sleeve |
| Connector Type | Miniature coaxial ClickLoc connector |
| Agency Approval | Not required (Option 00) |
The 330910-00-03-10-02-00 probe relies on specialized eddy-current probe scaling tuned specifically for narrow target side-clearance constraints where standard 8 mm probes experience sideview target interference. Installation requires gap voltage validation (-10 VDC targets) measured across the Proximitor signal conditioning terminals to ensure the tip is centered in its active linear voltage range. Proper radial and axial orientation prevents mutual inductive field distortion and provides cross-talk suppression when installed in close proximity to adjacent vibration sensors during severe rotor dynamics.
Q: How is the -10.0 VDC gap voltage set during mechanical probe mounting?
A: Rotate the threaded M10 probe casing into the mounting fixture while reading the DC output voltage at the Proximitor test terminals until -10.0 VDC is reached, confirming mid-scale electrical placement.
Q: Can a 1.0 metre 3300 NSv probe connect directly to a 5.0 metre 3300 NSv Proximitor?
A: No, a 1.0 metre probe requires a matching 4.0 metre 3300 NSv extension cable to establish the mandatory 5.0 metre total system electrical length.
Our production line was down due to a faulty Bently Nevada monitor. We found it in stock here and they shipped it via DHL immediately. Back in operation within 48 hours—truly a lifesaver for our plant.
Finding brand new, original modules is critical for our safety. This team delivers factory-fresh components with full certification. Their commitment to only selling new products makes them our most trusted partner.
We have sourced Honeywell and Schneider parts here for two years. Every shipment arrives well-packaged with original factory seals intact. Clear communication and the best lead times in the industry.