100% Genuine. 100,000+ Parts in Stock. Ready to Ship.

  • en

The Bently Nevada 991-06-50-01-CN serves as the primary 991 Thrust Transmitter utilized to execute axial shaft displacement measurement across machinery protection platforms.

Suffix Breakdown & Model Matrix

Option Code Option Description Technical Definition
991 Base Model Thrust Transmitter
-06 Full-scale Option 0.6 - 0 - 0.6 mm measurement range
-50 System Length Option 5.0 metres (16.4 feet) total system length calibration
-01 Mounting Option 35 mm DIN-rail clips installed
-CN Agency Approval Option ATEX/IECEx and Chinese NEPSI hazardous area marking

Hardware Specifications

Parameter Specification
Model 991-06-50-01-CN
Brand Bently Nevada
Origin USA
Product Type Thrust Transmitters
Measurement Parameter Axial shaft displacement (thrust)
Full-Scale Range 0.6 - 0 - 0.6 mm
System Length 5.0 metres (16.4 feet)
Output Signal Proportional 4-20 mA loop current
Mounting Interface 35 mm DIN-rail clips
Hazardous Area Approvals ATEX/IECEx and Chinese NEPSI (-CN option)
Power Consumption Loop-powered via 24 VDC field circuit

Eddy-Current Probe Scaling & Gap Voltage Validation (-10 VDC Targets)

The 991 transmitter processes input signals from non-contacting eddy-current proximity probes across a calibrated 5.0-metre system length. Commissioning requires physical gap voltage validation across raw probe output terminals to set the nominal baseline bias to -10 VDC when the machine rotor rests at mechanical mid-position. Precision eddy-current probe scaling translates mechanical shaft displacement into a proportional 4-20 mA current loop output across the 0.6 - 0 - 0.6 mm physical span.

Frequently Asked Questions

Q: How is operating power supplied to the 991 transmitter terminals?

A: Operating power is supplied directly through the 2-wire 4-20 mA current loop interface from the host control system or monitoring cabinet.

Q: What certification markings are provided under the -CN option code?

A: The -CN suffix indicates compliance with hazardous area certification standards, providing ATEX, IECEx, and Chinese NEPSI explosion-proof and intrinsic safety approvals.

Q: Can the 5.0-metre system length option be modified in the field using non-calibrated extension cables?

A: No, the total system length of 5.0 metres is factory-calibrated to match specific transducer coil inductance and cable capacitance; alter cable length disrupts output scaling.

Field Installation Guidelines

  1. Mount the transmitter module securely onto a standard 35 mm DIN rail inside an enclosure rated for the local hazardous area classification.
  2. Connect the matching 5.0-metre proximity probe extension cable coaxial connector to the transmitter input terminal, ensuring a clean and finger-tight joint.
  3. Validate static DC gap voltage using a multimeter across raw signal test terminals, adjusting mechanical probe depth until a target of -10 VDC is established.
  4. Connect 2-wire shielded twisted-pair cabling to the 4-20 mA output terminals according to intrinsically safe or explosion-proof wiring diagrams.
  5. Ground the field cable shield at a single point on the cabinet earthing bus bar to suppress electromagnetic interference and prevent ground loop noise.