100% Genuine. 100,000+ Parts in Stock. Ready to Ship.

  • en

The Bently Nevada 330104-00-09-05-11-05, also cataloged as the 330104 Proximity Probe, operates as a dedicated hardware component for high-precision vibration and position measurement within 3300 XL Machinery Protection System platforms. The probe tip establishes an electromagnetic field to register dynamic shaft displacement, transferring raw gap voltage alterations over a moisture-resistant coaxial transmission line with armor protection back to an external Proximitor Sensor.

Suffix Breakdown & Model Matrix

Code Option Category Technical Configuration
330104 Base Model 3300 XL 8 mm Proximity Probe, M10 x 1 Metric Thread
00 Unthreaded Length 0 mm
09 Overall Case Length 90 mm
05 Total Length 0.5 meter (1.6 feet)
11 Connector and Cable Type Miniature coaxial ClickLoc connector with connector protector, FluidLoc cable
05 Agency Approval CSA, ATEX, IECEx multiple approvals

Hardware Specifications

Parameter Specification
Model 330104-00-09-05-11-05
Brand Bently Nevada
Origin U.S.A.
Thread Type M10 x 1
Unthreaded Length 0 mm
Overall Case Length 90 mm
Cable Infrastructure FluidLoc cable with mechanical armor protection and ClickLoc connector protector
Certification CSA, ATEX, IECEx
Operating Temp -51 to +177 deg C
Power Consumption Passive sensor assembly (excited by external Proximitor loop)
Dimensions 90 mm case length, 0.5 meter total cable length
Weight Less than 1.0 kg nominal

Cross-Talk Suppression

When deploying multiple 330104-00-09-05-11-05 probe assemblies inside a single machine bearing housing for orthogonal (X-Y) radial vibration tracking, mechanical spacing must enforce cross-talk suppression. If the physical distance between adjacent 8 mm probe tips falls below 40 mm (1.6 inches), the high-frequency electromagnetic fields will intersect, inducing mutual interference and distorting the voltage-to-displacement calibration. Maintaining strict physical clearance ensures that each module executes independent displacement tracking without cross-channel modulation.

Frequently Asked Questions

Q: Can this 0.5-meter probe be directly connected to a standard 5.0-meter Proximitor Sensor?

A: No. Transducer loops require a matched electrical length calibration. A 0.5-meter total length probe must be paired with a 4.5-meter extension cable to complete the necessary 5.0-meter total system length required by the matching Proximitor module.

Q: What specific protection is provided by the combination of a FluidLoc cable and a connector protector?

A: The FluidLoc matrix prevents the internal capillary migration of oil or moisture through the cable jacket if damaged, while the integrated connector protector physically seals the ClickLoc coaxial junction against environmental fluid ingress at the machine boundary.

Field Installation Guidelines

  • Mounting Torque Limits: When threading the 90 mm metric case into the machine housing, use a calibrated torque wrench to limit mechanical load to a maximum of 33.9 N-m (300 in-lb) to prevent thread binding or casing distortion.
  • Armor Bend Radius Restrictions: The protective metal armor jacket shields the internal FluidLoc coaxial line but restricts flexibility. Maintain a minimum structural bend radius of 25.4 mm (1.0 inch) during routing to prevent internal conductor fracturing.
  • Shield Ground Separation: Ensure that the outer metallic structure of the armored cable and the ClickLoc connector protector assembly remains isolated from the machine ground. All signal shields must track back and terminate exclusively at the instrument rack or junction box common ground.