100% Genuine. 100,000+ Parts in Stock. Ready to Ship.

  • en

Configured for proximity probe signal conditioning and 4-20 mA current loop conversion in machinery protection networks, the Bently Nevada 990-04-50-01-00 (990 Vibration Transmitter) provides direct physical/electrical execution.

Suffix Breakdown & Model Matrix

Option Code Option Description Technical Definition
990 Base Model 2-Wire Vibration Transmitter
-04 Full-scale Option 0-4 mils pp (0-100 um pp) displacement amplitude range
-50 System Length Option 5.0 metres (16.4 feet) total calibrated system length
-01 Mounting Option 35 mm DIN rail clips pre-installed
-00 Agency Approval Option No hazardous area agency approvals required

Hardware Specifications

Parameter Specification
Model 990-04-50-01-00
Brand Bently Nevada
Origin USA
Product Type Vibration Transmitters
Input Device Accepts 1 non-contacting 3300 NSv Proximity Probe and extension cable
Full-Scale Range 0-4 mils pp (0-100 um pp)
System Length 5.0 metres (16.4 feet)
Output Signal Proportional 4-20 mA loop current
Maximum Loop Resistance 1000 ohm including cable at 35 VDC
Current Limiting 23 mA typical
Power Supply +12 to +35 VDC input at the transmitter terminal
Mounting 35 mm DIN rail clips
Operating Temp Standard 990 transmitter rating
Weight 2 kg (Shipping Weight)
Power Consumption Loop-powered via +12 to +35 VDC supply line

Gap Voltage Validation (-10 VDC Targets) & Cross-Talk Suppression

The module conditions raw eddy-current signal inputs generated by a 3300 NSv proximity probe across a tuned 5.0-metre system length. Installation protocol mandates gap voltage validation at the raw signal monitoring terminals to ensure a static baseline target of -10 VDC at mid-span. Internal filtering and shielded termination maintain cross-talk suppression and signal integrity when multiple transmitters are mounted adjacent to one another along shared cabinet DIN rails.

Frequently Asked Questions

Q: What is the maximum permissible loop impedance for this transmitter at maximum voltage?

A: At an operating voltage of 35 VDC, the total loop resistance limit is 1000 ohm, including all interconnecting field cabling resistance.

Q: How does the internal circuit handle over-range loop conditions?

A: The transmitter incorporates an internal current limiting circuit set to a typical threshold of 23 mA to protect downstream loop monitoring cards during over-range vibration events.

Q: What power input range must be supplied to the field connection terminals?

A: The module requires an external power supply delivering between +12 VDC and +35 VDC directly across the transmitter terminals to drive the 4-20 mA measurement loop.

Field Installation Guidelines

  1. Mount the transmitter module directly onto a grounded 35 mm DIN rail, verifying mechanical lock engagement.
  2. Connect the 3300 NSv proximity probe extension cable coaxial connector to the transmitter input interface, securing hand-tight.
  3. Validate static DC gap voltage using a multimeter connected to the test terminals, adjusting probe insertion depth to achieve -10 VDC.
  4. Connect 2-wire shielded cable from the control system 24 VDC analog input terminals to the transmitter power/output connections.
  5. Terminate the field cable shield to the cabinet earth bus bar at a single point to mitigate ground loops and electromagnetic interference.