Configured for proximity probe signal conditioning and 4-20 mA current loop conversion in machinery protection networks, the Bently Nevada 990-04-50-01-00 (990 Vibration Transmitter) provides direct physical/electrical execution.
| Option Code | Option Description | Technical Definition |
|---|---|---|
| 990 | Base Model | 2-Wire Vibration Transmitter |
| -04 | Full-scale Option | 0-4 mils pp (0-100 um pp) displacement amplitude range |
| -50 | System Length Option | 5.0 metres (16.4 feet) total calibrated system length |
| -01 | Mounting Option | 35 mm DIN rail clips pre-installed |
| -00 | Agency Approval Option | No hazardous area agency approvals required |
| Parameter | Specification |
|---|---|
| Model | 990-04-50-01-00 |
| Brand | Bently Nevada |
| Origin | USA |
| Product Type | Vibration Transmitters |
| Input Device | Accepts 1 non-contacting 3300 NSv Proximity Probe and extension cable |
| Full-Scale Range | 0-4 mils pp (0-100 um pp) |
| System Length | 5.0 metres (16.4 feet) |
| Output Signal | Proportional 4-20 mA loop current |
| Maximum Loop Resistance | 1000 ohm including cable at 35 VDC |
| Current Limiting | 23 mA typical |
| Power Supply | +12 to +35 VDC input at the transmitter terminal |
| Mounting | 35 mm DIN rail clips |
| Operating Temp | Standard 990 transmitter rating |
| Weight | 2 kg (Shipping Weight) |
| Power Consumption | Loop-powered via +12 to +35 VDC supply line |
The module conditions raw eddy-current signal inputs generated by a 3300 NSv proximity probe across a tuned 5.0-metre system length. Installation protocol mandates gap voltage validation at the raw signal monitoring terminals to ensure a static baseline target of -10 VDC at mid-span. Internal filtering and shielded termination maintain cross-talk suppression and signal integrity when multiple transmitters are mounted adjacent to one another along shared cabinet DIN rails.
Q: What is the maximum permissible loop impedance for this transmitter at maximum voltage?
A: At an operating voltage of 35 VDC, the total loop resistance limit is 1000 ohm, including all interconnecting field cabling resistance.
Q: How does the internal circuit handle over-range loop conditions?
A: The transmitter incorporates an internal current limiting circuit set to a typical threshold of 23 mA to protect downstream loop monitoring cards during over-range vibration events.
Q: What power input range must be supplied to the field connection terminals?
A: The module requires an external power supply delivering between +12 VDC and +35 VDC directly across the transmitter terminals to drive the 4-20 mA measurement loop.
Our production line was down due to a faulty Bently Nevada monitor. We found it in stock here and they shipped it via DHL immediately. Back in operation within 48 hours—truly a lifesaver for our plant.
Finding brand new, original modules is critical for our safety. This team delivers factory-fresh components with full certification. Their commitment to only selling new products makes them our most trusted partner.
We have sourced Honeywell and Schneider parts here for two years. Every shipment arrives well-packaged with original factory seals intact. Clear communication and the best lead times in the industry.