The FOXBORO FCM2F2, also cataloged as the FOXBORO RH914YZ Fieldbus Communication Module, operates as a dedicated hardware component for 2 Mbps fiber optic fieldbus extension within Foxboro I/A Series DCS networks.
| Parameter | Specification |
|---|---|
| Model | FCM2F2 |
| Part Number | RH914YZ |
| Brand | FOXBORO (Invensys / Schneider Electric) |
| Module Type | 2 Mbps Fiber Optic Fieldbus Extender |
| Platform Compatibility | Foxboro I/A Series DCS |
| Communication Rate | 2 Mbps deterministic data velocity |
| Physical Media | Fiber optic cabling interface |
| Isolation | Channel-to-channel and channel-to-bus isolation |
| Power Supply | Supplied via standard FBM/FCM baseplate |
| Operating Temp | 0 to 60 deg C |
| Protection Rating | IP20 enclosure protection |
| Weight | 0.25 kg |
| Origin | Mexico |
The FOXBORO FCM2F2 establishes high-speed, isolated communication links between remote Fieldbus Modules (FBMs) and centralized control processors. Utilizing a 2 Mbps optical signaling rate, this fiber optic extender maintains rigid 4-20 mA HART loop protocol translation over extended physical distances without signal attenuation. The fiber optic layer inherently enforces complete galvanic channel-to-bus isolation, blocking common-mode voltages and eliminating localized ground loops. This optical isolation setup prevents electromagnetic interference from corrupting critical analog process measurements or disrupting the timing parameters required for accurate cold junction compensation across the distributed node network.
Q: What are the backplane power supply considerations when installing an FCM2F2 on an existing baseplate slot?
A: The module draws its operating current directly from the shared baseplate power bus rails. System configuration requires tracking the cumulative current budget of all populated FCM and FBM modules to verify that total consumption matches the local rack power supply limitations.
Q: How does the module handle a sudden loss of fiber optic signal continuity?
A: If optical link degradation or signal loss occurs, the internal communication logic triggers the on-board LED diagnostics and broadcasts a fieldbus fault packet to the DCS processor, driving dependent loops to their configured safe default states.
Q: Can the FCM2F2 module firmware be updated over the active fiber optic fieldbus link?
A: Firmware flash compatibility parameters restrict live, remote updates over the 2 Mbps optical link. Upgrades must be conducted through specialized system management tools via a direct local bus connection while the module is offline.
Our production line was down due to a faulty Bently Nevada monitor. We found it in stock here and they shipped it via DHL immediately. Back in operation within 48 hours—truly a lifesaver for our plant.
Finding brand new, original modules is critical for our safety. This team delivers factory-fresh components with full certification. Their commitment to only selling new products makes them our most trusted partner.
We have sourced Honeywell and Schneider parts here for two years. Every shipment arrives well-packaged with original factory seals intact. Clear communication and the best lead times in the industry.