The Foxboro FBM228 P0922QS, also cataloged as the FBM228 P0922QS FOUNDATION Fieldbus H1 Communication Module, operates as a dedicated hardware component for multi-channel digital fieldbus data acquisition within Foxboro I/A Series and Foxboro Evo DCS networks.
| Parameter | Specification |
|---|---|
| Model | FBM228 P0922QS |
| Brand | Foxboro |
| Origin | USA |
| Weight | 2.0 kg |
| Dimensions | 22.0 W x 124.0 H x 126.0 D mm |
| Operating Temp | 0 to +60 deg C |
| Power Consumption | 24 VDC backplane input (redundant support enabled) |
| Channel Count | 4 isolated FOUNDATION Fieldbus H1 channels |
| Physical Layer | IEC 61158-2 (H1, 31.25 kbit/s) |
| Galvanic Isolation | 600 VAC channel-to-channel and channel-to-system isolation |
| System Interface | Redundant Foxboro Fieldbus interface |
| Memory Architecture | 16 MB SDRAM, 32 MB Flash |
| Environmental Rating | Class G3 conformal coating for harsh environments |
The FBM228 P0922QS provides dedicated FOUNDATION Fieldbus H1 connectivity by combining IEC 61158-2 physical layer compliance with 600 VAC channel-to-channel galvanic isolation. This architecture isolates each individual H1 segment, preventing ground loops and field-induced common-mode electrical noise on one bus from propagating to adjacent channels or the internal DCS backplane. The module manages bi-directional digital traffic across four independent segments at a fixed transfer rate of 31.25 kbit/s, enabling real-time multi-variable field instrument data acquisition and continuous asset status monitoring without compromising backplane communication determinism.
Q: Does the FBM228 P0922QS module directly supply field power to connected H1 segment devices?
A: No, the module executes signal processing and communications only. Field devices require an external, dedicated FOUNDATION Fieldbus power supply and conditioned termination network on each H1 segment.
Q: Can maintenance personnel perform hot-swapping on an active FBM228 module in a redundant pair?
A: Yes, the hardware supports online replacement. When plugged into a redundant baseplate configuration, removing the active module triggers an immediate bumpless failover to the secondary module without dropping active H1 communications links.
Align the FBM228 module with the baseplate mounting slot and press firmly until the mechanical locking latch engages fully. Ensure that all field wiring conforms strictly to IEC 61158-2 physical layer standards, using dedicated shielded twisted-pair Fieldbus cable. Connect cable shields to a single earth ground point at the Fieldbus power supply to prevent circulating ground currents from corrupting the 31.25 kbit/s digital signal. Maintain a minimum engagement of 5 threads on conduit entries, verify that external segment terminators reside at both physical ends of each H1 trunk, and confirm adequate cabinet convection to keep ambient operating temperatures between 0 and +60 deg C.
Our production line was down due to a faulty Bently Nevada monitor. We found it in stock here and they shipped it via DHL immediately. Back in operation within 48 hours—truly a lifesaver for our plant.
Finding brand new, original modules is critical for our safety. This team delivers factory-fresh components with full certification. Their commitment to only selling new products makes them our most trusted partner.
We have sourced Honeywell and Schneider parts here for two years. Every shipment arrives well-packaged with original factory seals intact. Clear communication and the best lead times in the industry.